Baxter Laser Particle Size Analyzer BT-9300ST
Product Details
Core Specifications
Applications
Detailed Description
Product introduction
BT-9300ST laser particle size analyzer is a miniaturized, integrated laser particle size analyzer using dual-lens technology. Its dual-lens optical system allows both forward and backward scattered light signals to be effectively received, expanding the measurement range and improving repeatability and accuracy. At the same time, the integrated design makes the system more compact, with short pipelines, small size, light weight, and high cost performance.

BT-9300ST has special functions such as automatic testing, automatic centering, automatic water inflow, automatic drainage, automatic elimination of bubbles, and automatic cleaning. Intelligence not only simplifies the operation, but also reduces the impact of human factors on the test results, making its main indicators such as range, repeatability, accuracy and resolution reach international standards. This instrument is especially suitable for use in small and medium-sized laboratories of small and medium-sized powder production and application enterprises, universities and research institutes. It is a reliable particle size monitoring method for powder quality control, production process control, powder application research, and new powder material research.
BT-9300ST is a laser particle size analyzer with a wide range of sales. It is not only sold to 30 domestic provinces and municipalities, but also exported in batches to more than 20 countries and regions including the United States, Germany, South Korea, Brazil, Russia, Pakistan, India, Vietnam, and Malaysia. As of the end of 2024, domestic sales of BT-9300ST have exceeded 2,300 units. Its exquisite design and sophisticated manufacturing technology, excellent repeatability and accuracy, one-button operation and other outstanding features have been well received by users at home and abroad.

Basic performance indicators
| Test range | 0.05-1500μm |
| Measurement principle | Mie scattering theory (default), Fisher diffraction theory (optional) |
| Accuracy and Repeatability Error | ≤1% (national or international standard sample D50 deviation) |
| Accuracy calibration | Yes, this function ensures the accuracy of the instrument |
| Bimodal resolution | Grade A (JJF1211-2008, JJG167-2020) |
| Laser light source | High power fiber laser |
| Photodetector | 88 (forward, side and rear) |
| Optical system | Dual lens optical system (patented technology) |
| Wet dispersion system | Water medium automatic circulation dispersion system (built-in anti-dry burning ultrasonic disperser, 0-50W continuously adjustable, with automatic water inlet, automatic discharge, Automatic cleaning function) |
| Measurement mode | One-button mode (SOP)/manual mode/continuous mode |
| Fastest single test time | ≤1S |
| Data security | FDA 21 CFR PART 11 |
| Related Pharmacopoeia | USP429 / EP2.9.38 / Chinese Pharmacopoeia 0982 |
| Related standards | ISO 13320-2020,GB / T 19077-2024,GB/T 41949-2022 |
| power supply | 100-240VAC,50/60Hz,2.5A |
Application areas
●Various non-metallic powders: such as heavy calcium, light calcium, talc powder, kaolin, graphite, wollastonite, brucite, barite, mica powder, bentonite, diatomaceous earth, clay, silicon dioxide, garnet, zirconium silicate, zirconium oxide, magnesium oxide, zinc oxide, etc.
●Various metal powders: such as aluminum powder, zinc powder, molybdenum powder, tungsten powder, magnesium powder, copper powder, rare earth metal powder, alloy powder, etc.
●Other powders: such as lithium battery materials, catalysts, phosphors, cement, abrasives, medicines, pesticides, food, coatings, dyes, river sediment, ceramic raw materials, chemical materials, nanomaterials, paper filling coatings, various emulsions, etc.
Outstanding features
●Optical path system: It adopts Baxter's patented technology dual-lens optical path system, which is equipped with photoelectric detectors in the front, side and rear directions, ensuring accurate reception of scattered light signals of all particles within the measurement range, ensuring accurate and reliable results.
●Automatic water inlet function: Built-in water suction pump and water level detector can absorb water into the automatic circulation and dispersion system, completely changing the design of relying on pressure or manual water inlet, simplifying operation, improving accuracy, and improving efficiency.
●Sample preparation system: Built-in automatic circulation, dispersion, water inlet, drainage, water level monitoring and other systems ensure that samples are fully dispersed and test results are stable and reliable.
●Automatic testing: Automatic centering, circulation, dispersion, testing, cleaning, saving, and printing functions completely change the situation where the reliability of particle size test results depends entirely on the operator, making the results more objective and accurate.
good repeatability

Repeatability when testing the same sample continuously

Repeatability during repeated sampling tests
good accuracy

Verified by standard samples, the results are consistent with the nominal value
Product Overview
Baxter Laser Particle Size Analyzer BT-9300ST adopts dual-lens technology and has automatic testing and automatic alignment functions. It has a wide measurement range, high repeatability and accuracy, and is suitable for particle size detection of a variety of powders. Its compact design, efficient automated operation and wide range of applications make it an ideal choice for powder production and scientific research.