The maximum operating temperature of TANK MAX super microwave can reach 300°C and the maximum operating pressure can reach 20MPa. Even insoluble samples can be easily digested completely. The single reaction chamber pre-pressurized design allows samples of different properties and different reaction systems to be processed simultaneously. No matter what kind of digestion experiment, it can be handled with ease.
A single sample only needs 2mL of acid solution to complete the digestion. After digestion, there is no need to chase acid and the volume can be directly adjusted. The experimental efficiency is more than doubled. The digestion tube can be made of PTFE-TFM, high-purity quartz and other materials, and the cost is more than 60% lower than that of the microwave digestion tank. If you choose an ordinary glass test tube, the use cost can be as low as negligible.
Easy Load is a convenient loading design. The digestion tube can be inserted into the tube cap, and the sample rack and lined tank do not need to be aligned, which saves operation time and greatly reduces the error rate. The entire process can be run with one click, without manual assistance or software guidance, and you can enjoy a new experience of automated digestion. The four-fold safety architecture of predictive protection mechanism, active safety protection, passive safety protection, and acid mist protection protects the safety of your experiments. TANK MAX super microwave, with super digestion capabilities, brings you super high experimental efficiency, minimalist operation experience, and comprehensive safety guarantee!
Super digestion ability

Ultra-high digestion temperature and digestion pressure, bid farewell to inability to digest
With a maximum operating temperature of 300°C and a maximum operating pressure of 20MPa, conventional samples are digested more thoroughly, and insoluble samples can also be easily digested completely.
No sample classification is required, the reaction temperature is completely consistent, and the experimental results are more accurate and reliable
With a single reaction chamber pre-pressurized design, the digestion tube does not need to withstand reaction pressure, and different samples and different reagent systems can be digested at the same time. Moreover, the temperature and pressure conditions of all samples are completely consistent, making the digestion process more accurate and reliable, ensuring the reproducibility and traceability of the experiment.
Reagents such as aqua regia and hydrofluoric acid can be used, and digestion experiments are no longer limited.
The self-cleaning anti-corrosion high-pressure pipeline design can withstand most digestion reagents including aqua regia, hydrofluoric acid, and perchloric acid, making the instrument more widely used.
Ultra-high experimental efficiency

Rapid heating and rapid cooling improve the speed of digestion experiments
Using single-feed microwave coupling technology, the coupled microwave field is efficiently fed into the reaction cavity through a large-diameter waveguide port. The microwave energy utilization rate is high, the microwave field is evenly distributed, the heating rate is faster, and the digestion efficiency is higher.
There is no need to rush for acid, and the volume can be directly adjusted after digestion is completed, further improving experimental efficiency.
A single sample only needs 2 mL of acid solution to complete the digestion, and the volume can be directly adjusted without rushing for acid, which more than doubles the experimental efficiency. In addition, extremely low reagent consumption can significantly reduce acid gas emissions and is more environmentally friendly.
Minimalist operating experience
Easy Load
No complicated assembly is required, just insert the tube cap to complete the canning process; the sample rack and lining cans do not need to be aligned and can be quickly placed at any angle, allowing you to experience a minimalist digestion tube loading process.
Extremely low cost of use, the first choice for cost reduction and efficiency improvement
Digestion tubes can be made of PTFE-TFM, high-purity quartz and other materials, and the cost of use is more than 60% lower than that of microwave digestion tanks; if you choose ordinary glass test tubes, the cost of use is negligible.
All in one The whole process can be run with one click
Redefining one-click operation, there is no need for manual assistance to lock the furnace cavity or software guidance. The instrument automatically closes the safety door, automatically locks the furnace cavity, automatically prepressurizes and performs digestion. After digestion is completed, it automatically enters water cooling, automatically releases pressure, and automatically takes out the can, giving you a new experience in automated digestion.
Comprehensive security
The first level: Predictive protection mechanism to nip problems in the bud
The instrument has a built-in intelligent temperature and pressure warning model, which can predict the pressure value of the subsequent experimental process based on the current temperature, pressure value and temperature and pressure rising rate, combined with the data model. When the predicted value exceeds the limit, an alarm will be prompted, eliminating overpressure risks in the early stages of the experiment.
The second level: active safety protection
Programmable active pressure relief system, when the pressure exceeds the safety setting during operation, the instrument automatically opens the pressure relief and releases the pressure; the self-controlled safety pressure relief module can manually release the pressure to ensure safe use.
The third level: passive safety protection
Even if the active pressure relief system fails, the instrument is also equipped with an independent micro-opening pressure relief device and a terminal overpressure protection device. When the pressure continues to rise, it will be automatically triggered in sequence to release excess pressure. The self-locking high-pressure chamber has a self-locking pressure resistance of up to 30MPa. Even if the power is interrupted during operation, the furnace chamber can be self-locking and sealed, ensuring that experimental operations remain absolutely safe under extreme circumstances.
The fourth level: acid mist protection
The safety protection door can prevent the acid gas from contacting the outside world, and cooperates with the automatic acid gas discharge system to promptly discharge the acid gas that escapes during the can opening process to prevent the acid gas from causing harm to experimental personnel and instruments.
Workflow

TANK MAX technical parameters
power supply | 220~240VAC 50/60Hz 20A |
Working environment temperature | 0~40℃ |
Relative humidity of working environment | 15~80%RH |
microwave source | 2450MHz, variable frequency magnetron high-energy microwave field emission, non-pulse continuous microwave output |
Microwave output power | 1500W |
cooling system | Cooling circulating water system, cooling range: 5-40℃ |
software system | Android system, graphical software interface |
Digestion tank type | 6-bit, 10-bit, 18-bit, 24-bit, 28-bit, PTFE-TFM, quartz, glass and other materials optional |
Wide range of applications

TANK MAX super microwave can be widely used in analysis fields such as food, medicine, environment, chemical industry, geology and minerals, new materials, etc. It is especially suitable for batch processing of insoluble samples such as polymers, ceramic materials, rare metals and their oxides.

Product Overview
The maximum operating temperature of TANK MAX super microwave can reach 300°C and the maximum operating pressure can reach 20MPa. Even insoluble samples can be easily digested completely. The single reaction chamber pre-pressurized design allows samples of different properties and different reaction systems to be processed simultaneously. No matter what kind of digestion experiment, it can be handled with ease.
Send an inquiry
Recommended Products
MASTER series high-throughput sealed microwave digestion/extraction/synthesis workstation
Negotiable
Model:MASTER
MDS-15 closed high-throughput microwave digestion/extraction/synthesis workstation
Negotiable
Model:MDS-15