Xi'an TianLong Science and Technology Co., Ltd.

Main products: Nucleic Acid Purification/Extraction System, PCR, Thermostat, Multi-Parameter Water Quality Analyzer

Gold Member Business License 29 Years in Business
Home/ Products/ Nucleic Acid Purification/Extraction System/ Tianlong Technology fully automatic nucleic acid extraction instrument GeneRotex
Tianlong Technology fully automatic nucleic acid extraction instrument GeneRotex Premium Instruments

Tianlong Technology fully automatic nucleic acid extraction instrument GeneRotex

PRICE US$ 27972.00
Model:GeneRotex
Brand:TIANLONG
Origin:China

Product Details

Core Specifications

Instrument typemagnetic bead method
Automatic degreeDedicated fully automatic
Number of samples processed in a single batch96, 48, 24
Single batch sample processing time10-30

Applications

Medical & HealthcareBiotechnology & Life SciencesPharmaceuticals / Biopharmaceuticals

Detailed Description

GeneRotex series
Fully automatic nucleic acid extraction instrument


Tianlong Technology's fully automatic nucleic acid extractor GeneRotex uses independently developed Rotary Mixing Technology (RMT), which performs rapid 360° rotation and mixing based on slow up and down reciprocating motion. This technology has applied for an invention patent (Patent No. ZL201710435931.8), which can control the risk of cross-contamination caused by nucleic acid aerosols to a lower level and run more quietly. In addition, design concepts such as "independent modules" and "one machine, three models" are also fully reflected in this series, which can meet the diverse downstream experimental testing needs.

  • Rotary nucleic acid extraction technology
  • Extraction modules 24, 48, 96 are optional
  • Various measures to control pollution
  • Ultra-quiet operation

01

Various extraction modules


96 throughput: The innovative 6×16 extraction module, equipped with a self-developed 96 deep-well plate and a single six-strip tube, ensures high-throughput extraction while overcoming the shortcomings of inflexible throughput and waste of reagents in traditional extraction modules. From now on, you can choose from 1 to 96.
48-throughput: A large-system extraction solution with a sample volume of 1 mL, combined with self-developed consumables, makes ultra-sensitive detection of infectious pathogens as low as 2 copies/mL possible.
24-throughput: Using an innovative 5mL ultra-large sample volume and a maximum processing volume of 15mL, it can meet the requirements of various testing projects such as prenatal DNA testing and tumor targeted drug guidance.


02

Flexible control methods

Built-in 7-inch full-color LCD screen, touch operation, or one-click operation by scanning the QR code.


03
Efficient pollution control

Rotating mixing: In order to minimize the generation of aerosols, this equipment adopts independently developed RMT technology. Compared with traditional oscillating mixing technology, the generation of aerosols is greatly reduced. The risk of false positives caused by cross-contamination is more effectively controlled, further ensuring the accuracy of experimental results.

Negative pressure HEPA: The instrument has a built-in replaceable high-efficiency air filter and a negative pressure exhaust device, which greatly reduces the risk of pollution from exhaust gases.

UV disinfection: The instrument has a built-in UV lamp and can flexibly set the disinfection time.
Automatic hatch: An independent motor-driven component eliminates the need to manually open and close the hatch, reducing operator contact with potential biological hazards and reserving space for automatic sampling equipment.


04

Good reagent compatibility

As the fifth generation of Tianlong Technology’s fully automatic nucleic acid extraction instrument, GeneRotex 96 inherits the classic 96-well deep well plate and innovative single six-strip tube, and is compatible with all types and specifications of Tianlong’s extraction kits. In addition, this series of products is equipped with special large-system nucleic acid extraction reagents, which can greatly improve work efficiency and detection sensitivity.


05

High extraction efficiency

The nucleic acid recovery rate is >95%, the detection rates of 10lU/mLHBV and 30lU/mLHCV are both ≥98%, and it can even extract 2 copies/mL of COVID-19 standard.

Instrument modelGeneRotex 96GeneRotex 48GeneRotex 24
Medical device registration certificateShaanxi Machinery No. 20150054Shaanxi Machinery No. 20150054Shaanxi Machinery No. 20150054
sample throughput1-961-481-24
Processing volume30-1000μL50-3000μL50-15000μL
Recommended sample size200μL1000μL5000μL
Applicable consumables96-well deep well plate,
Customized single six-unit pipe
Customized 48-well deep well plateCustomized ultra-large volume single seven-piece pipe
Rotation speed≤3000rpm
Temperature control rangeCracking heating: room temperature ~ 120℃ Elution heating: room temperature ~ 120℃
Mixing methodSwirl to mix
operating languageBuilt-in Chinese/English operating languages, which can be switched freely
Operation mode7-inch full-color LCD touch screen or code scanner control
program storageBuilt-in mode program, can store up to 10,000 programs
Program managementFlexible to create, edit, apply and delete programs
automatic hatchMotor driven automatic switch experimental cabin
QR code scanningCan be connected to an external scanner, automatically recognizes applications after scanning, and runs them with one click
Power outage protectionYou can freely choose whether to continue running the experiment when the power is unexpectedly cut off and then restored.
pollution controlNegative pressure HEPA exhaust filter module with built-in UV disinfection module
Instrument interfaceUSB interface
weight45kg
Overall dimensions490mm (L)×510mm (W) ×480mm (H)490mm(L) x540mm(W) X480mm(H)
Supply voltageAC 220V,50Hz
temperature range10℃~30℃
relative humidity≤80%


Product Overview

The GeneRotex series of fully automatic nucleic acid extractors adopt self-developed rotary mixing technology, which can effectively reduce the risk of cross-contamination caused by aerosols and operate more quietly. The equipment provides 96, 48, and 24 flux modules, with flexible operation methods, efficient contamination control and good reagent compatibility, and is suitable for diverse downstream experimental detection needs.

Send an inquiry

Recommended Products