Tianlong Technology fully automatic medical PCR analysis system Gentier96R
Product Details
Core Specifications
Applications
Detailed Description
Product overview
Gentier 96E/96R is a high-throughput, multi-target, and high-precision real-time fluorescence quantitative PCR detection system independently developed by Tianlong Technology. This product has many advantages such as scientific and efficient temperature control system and photoelectric system, powerful and easy-to-use software analysis functions, and humanized control methods. It can easily realize downstream multiple gene detection, quantitative analysis, SNP analysis, melting curve analysis and other applications. It is currently widely used in medical institutions at all levels, centers for disease control, animal epidemic control, customs, scientific research institutes, public security criminal investigation evidence identification centers, veterinary stations, food companies, dairy factories and other industries.
- Maximum heating rate ≥6.1°C/s
- Temperature uniformity ±0.1°C
- Complete detection in 7 seconds
Instrument features
01
Synchronous detection of all channels
A variety of conventional excitation and detection channels, compatible with most fluorescent dyes and probe types, to achieve absolute quantification, relative quantification, genotyping and other detections;
Gentier 96E/96R FRETThe introduction of the (fluorescence energy resonance transfer) channel meets users' needs for low fluorescence background value and high-sensitivity detection, making detection more convenient, professional and accurate.

02
Diverse operating methods
On the basis of inheriting the classic one-to-one control of an external computer, it creatively introduces remote control within the local area network and the stand-alone local operation mode of the instrument;
built-in10.4The 1-inch touch screen is equipped with self-developed control software, making operations such as experimental settings, experimental real-time monitoring, and instrument settings more convenient.
03
Accurate and efficient temperature control system
based onPeltierThe effect of multiple semiconductor refrigeration chips is arranged inBlockUnder this condition, the temperature uniformity, accuracy, heating and cooling rate, etc. have been significantly improved, shortening the experimental cycle;
The realization of the temperature gradient function eliminates the need to repeatedly explore the annealing temperature in the past and improves experimental efficiency.

04
Scientific and reasonable optical system
Fluorescence excitation light source adopts high brightness and long lifeLED, the fluorescence detection system is maintenance-free for life;
The optical system is located on the top of the instrument. During operation, the top excites and scans, so there is no need to worry about the adverse effects of dust in the holes on the results;
Compact optical system integrated6/4A fluorescence detection channel has achieved multiple technological breakthroughs; at the same time, constant temperature control has been added to ensure the accuracy and stability of fluorescence detection;
Just need7Completed in seconds96Hole position6/4Hole-by-hole scanning of fluorescence channels with high efficiency and no fluorescence edge effect.
| Instrument model | Gentier 96E | Gentier 96R |
| Detection flux | 96 | |
| Applicable consumables | 0.2ml 96-well plate, 8 tube strips, single tube (transparent, frosted, milky white are suitable) | |
| Fluorescence channel | 6 | 4 |
| Suitable for fluorescein | Channel 1: EAM, SYBR Green l, SYTO 9, vaGreen, LC Green Channel 2: HEX, VIC, TET, JOE Channel 3: ROX, Texas Red Channel 4: Cy5 Channel 5: Alexa Fluor 680 Channel 6: FRET | Channel 1: EAM, SYBR Green l, SYTO 9, vaGreen, LC Green Channel 2: HEX, VIC, TET, JOE Channel 3: ROX, Texas Red Channel 4: Cy5 |
| reaction system | 0~100μL | |
| Module temperature | 0℃~100.0℃ | |
| linear range | 1~1010 copies | |
| Sample test repeatability | Ct value CV≤0.5% | |
| sample linearity | /r/ ≥0.999 | |
| Control method | Stand-alone operation: Use the instrument’s 10.4-inch touch screen and software system to create new experiments and run them; Network operation: (1) PC direct connection: After the instrument is connected to the PC through a point-to-point network, the application software on the computer is used to implement operations such as experimental setup, operation monitoring, and data analysis; (2) LAN access: By setting the network parameters of the instrument, the instrument can be connected to the local LAN, so that any computer in the LAN can monitor and control the operation of the instrument. Data synchronization and analysis operations. | |
| Automatic sample cabin | The sample compartment can be automatically ejected/closed by touch screen control When popping up, you can touch the sample compartment to automatically close it. | |
| Power outage protection | It has the function of automatically resuming the experiment when the power is restored after a power outage. There is no need to wait for the PC and software to open. | |
| Data transmission | Experimental data can be imported and exported through USB flash drive | |
| storage | Can be stored≤1000 experiment data files | |
| light source | High-brightness, long-life maintenance-free LED light source | |
| detector | Photodiode (PD) | |
| Detection position | Top excitation, top scan | |
| Detection method | Six fluorescence channels are scanned hole by hole at the same time, without fluorescence edge effects | 4 fluorescence channels are scanned hole by hole at the same time, without fluorescence edge effects |
| Detection duration | Complete detection of all 96 wells in 6 fluorescence channels within 7 seconds | Complete detection of all 96 wells in 4 fluorescence channels within 7 seconds |
| Excitation light wavelength | Channel 1: 465nm Channel 2: 527nm Channel 3: 580nm Channel 4: 632nm Channel 5: 680nm Channel 6: 465nm | Channel 1: 465nm Channel 2: 527nm Channel 3: 580nm Channel 4: 632nm |
| Detection light wavelength | Channel 1: 510nm Channel 2: 563nm Channel 3: 616nm Channel 4: 664nm Channel 5: 730nm Channel 6: 616nm | Channel 1: 510nm Channel 2: 563nm Channel 3: 616nm Channel 4: 664nm |
| Fluorescence linear | r≥0.990 | |
| Fluorescence detection dynamic range | Fluorescence detection dynamic range can be adjusted according to reagents | |
| Hot lid temperature | Room temperature~110℃ | |
| Constant pressure hot lid | Compatible with consumables of different heights | |
| Module temperature | 0℃~100℃ | |
| Module temperature control principle | Peltier effect, semiconductor refrigeration technology | |
| Maximum heating/cooling rate | ≥6.1℃/s;≥5.0℃/s | |
| temperature uniformity | ≤±0.1℃ | |
| Temperature accuracy | ≤±0.1℃ | |
| Gradient temperature width | 1℃~40℃ | |
| Gradient temperature number | 12 columns | |
| Special temperature setting function | Supports thermal gradient PCR experiments, long fragment PCR (Long PCR), and landing PCR (Touch Down PCR) | |
| Analysis function | Qualitative analysis, absolute quantitative analysis, relative quantitative analysis, end-point fluorescence analysis, melting curve analysis,High resolution melting curve,High resolution melting curve,SNP analysis etc. | |
| Report customization features | Pre-saved various industry experiment report templates Support clinical report sheet management system | |
| Rights management function | The administrator account can limit the "manual threshold setting", "run settings", "run experiments", "analyze data" and other functions of the ordinary account. Realize the management of instrument usage rights of ordinary accounts | |
| Resource sharing function | After the instrument is connected to the PC, both parties can synchronize and share experimental data through operations such as uploading and downloading. | |
| Transport lock function | Automatically detect shipping lock status and make lock/unlock settings | |
| Fault management | Intelligently determine the type of fault and perform fault management | |
| LIS function | Can export CSV, Excel, TXT and other formats, open data port, and supports interconnection with LIS system simultaneously. | |
| operating system | Win 7、 Win10 | |
| Interface type | 1 Ethernet port, 1 front USB, 2 rear USB | |
| Overall dimensions | 355mm×475mm×484mm | |
| weight | 30kg | |
| Input power | AC220V,50Hz | |
| Power consumption | 900VA | |
| working environment | Temperature: 10℃~30℃ Relative humidity: 20%~85% | |
Tianlong Technology fully automatic medical PCR analysis system Gentier96R
Product Overview
Gentier 96E/96R is a high-throughput, multi-target, high-precision real-time fluorescence quantitative PCR detection system developed by Tianlong Technology. It has efficient temperature control and photoelectric systems, powerful software analysis functions and humanized control methods, and is suitable for multiple applications such as multiple gene detection and quantitative analysis. The product has the characteristics of rapid detection, high sensitivity, diverse operation methods, precise temperature control, scientific optical system, etc., and is widely used in medical treatment, disease control, scientific research and other fields.