Beishide Istrument Technology (Beijing) Co., Ltd.

Main products: Vapor Sorption Analyzer, Surface Area and Pore Size Analyzer, Density Meter, High-Pressure Adsorption Analyzer, Chemisorption Analyzer, Pore Size/Porosity Analyzer, Multi-Component Competitive Adsorption Analyzer, Other Surface Testing

Gold Member Business License 20 Years in Business
Home/ Products/ Vapor Sorption Analyzer/ BSD-VVS&DVS multi-station gravimetric gas vapor adsorption instrument
BSD-VVS&DVS multi-station gravimetric gas vapor adsorption instrument

BSD-VVS&DVS multi-station gravimetric gas vapor adsorption instrument

PRICE US$ 69930.00 - US$ 139860.00
Model:BSD-VVS&DVS
Brand:Beishide Instrument
Origin:China

Product Details

Core Specifications

Instrument typeDynamic vapor adsorption instrument
Weighing range10~2000mg
Weighing resolution1ug
temperature rangeRoom temperature~50℃
Humidity range-180℃~50℃,
Humidity accuracyAccuracy is better than ±0.1℃, stability is better than 0.1℃

Applications

Environmental & WaterEnergy & Utilities

Detailed Description

Main Function / Main Function


◆ Vacuum gravimetric vapor adsorption and desorption isotherm (VVS);

◆ Vacuum gravimetric vapor isobaric adsorption and desorption rate (VVS);

◆ Vacuum gravimetric gas adsorption and desorption isotherm (VGS);

◆ Vacuum gravimetric gas isobaric adsorption and desorption rate (VGS);

◆ Vacuum gravimetric temperature programmed degassing (TPD);

◆ Dynamic gravimetric vapor isobaric adsorption and desorption rate (DVS);

◆ Dynamic gravimetric vapor isobaric adsorption and desorption rate (DVS);

◆ Dynamic gravimetric gas adsorption-desorption isotherm (DGS);

◆ Dynamic gravimetric gas isobaric adsorption and desorption rate (DGS);

◆ Dynamic gravimetric temperature programmed desorption (TPD);

◆ Dynamic gravimetric temperature programmed reduction (TPR);

◆ Dynamic gravimetric temperature programmed oxidation (TPO);

◆ Evaluation of multi-component competitive adsorption by dynamic gravimetric method;

◆ Distillation and purification of reagents;

◆ Vacuum thermogravimetric: Vacuum thermogravimetric analysis can be performed;

◆ Can be upgraded to adsorb corrosive vapors and gases (such as SO2, H2S, NH3, etc.);


Report Content / Report Content


◆ Vacuum degassing thermogravimetric report

◆ Adsorption and desorption isotherm

◆ Adsorption and desorption speed

◆ BET single point method specific surface

◆ Langmuir specific surface

◆ Mesopore analysis by BJH method

◆ T-plot micropore analysis

◆ D-R method micropore analysis

◆ HK method micropore analysis


Performance Parameters / Performance Parameters


test function

adsorption-desorption isotherm, adsorption kinetics and other adsorption performance tests

constant voltageAdsorption kinetics

Constant pressure adsorption kinetic analysis (constantPressure adsorption and desorption rate)

Number of analysis bits

Optional4or8analysis bits;

Simultaneous analysis of multiple analysis positions, aiming at the slow constant pressure adsorption rate and low adsorption test efficiency of the gravimetric method,substantially improvedTest efficiency and accelerate scientific research progress;

The analysis environment of multiple analysis positions is completely consistent, and the subtle adsorption performance differences of the same batch of materials can be known;

Microbalance

resolution/range

Original imported industrial microbalance,1ug/5000mg(0.1ug/500mgOptional);

Compared with similar products, the measuring range is improved2-5times,Broaden the range of sample loading and increase sampling representativeness,Improve accuracy;

Test gas type

water vapor, organic vapor, andCO2, alkanes and olefins and other non-corrosive gases;

Is it optional?NH3,SO2wait

corrosionsexual gasadsorbate

yes

Fully automatic cycle adsorption test

(recommended configuration)

Fully automatic constant pressure temperature swing adsorption and desorption

Fully automatic constant temperature pressure swing adsorption and desorption

Fully automatic temperature and pressure swing adsorption and desorption

Fully automatic cycle adsorption and desorption life evaluation

Degassing furnace and constant temperature bath switching method

(recommended configuration)

Fully automatic switching

Especially for fully automatic cycle adsorption life evaluation

AdsorptionTest temperature

thermostatic bath,-5℃~150℃, precision±0.1℃;

steamAnti-condensation

The gas circuit system is fully constant temperature.Room temperature~60℃, precision0.1℃;

Steam generation method

"Static evaporation" method

“Carrier gas mix”flowLaw

steam"Humidity/Partial Pressure" control range

0.1%~98% P/P0

2%~98% P/P0 ,lowerP/P0 Optional

Reagent tube liquid reagent capacity

120ml

120ml

Patented reagent saturated condensation recovery technology improves reagent utilization and reduces reagent consumption

degassingactivationpreprocessing

Vacuum degassing, recommend molecular pump high vacuum degassing function

Room temperature~400℃, precision±0.1℃;

Normal pressure purge degassing

Room temperature~300℃, precision±0.1℃;

Visualized programmed heating and degassing

32Programmed temperature rise in stages to prevent samples from flying;

The constant weight process of the sample can be visualized in real time to accurately determine whether the sample is completely degassed;

buoyancyCorrection

Mode 1: Buoyancy calculation mode(default);

Mode 2: Blank buoyancy background subtraction mode;

modelthree: Background subtraction curve mode;

Blank bit synchronization test

Supports blank bits as background and buoyancy deduction for simultaneous testing;

Eliminate systematic errors,SubstantiallyImprove test accuracyand stability;

Remove steamvacuumsystem

Yes, dual pump vacuum system

High vacuum mechanical pump+Steamgaspump

The steam pump has a program-controlled steam removal function

Molecular pump high vacuum system

(recommended configuration)

Original imported molecular pump,Vacuum degree is better than10E-6 torr

Can significantly reduce vapor background residue and improve test accuracy

Segmented pressure measurement

Dual pressure sensorsegmental testing;

Original imported capacitive film pressure sensor;

Air controlled high vacuum damper valve

Original imported air-controlled high vacuum baffle valve;

Large diameter, air control and zero heat generation;

mass flow controller

Imported high-precision mass flow controllerMFC

Achieve precise gas and vapor concentration control


Test Report/Data Report

hkkNoC7ZQ6ZutjkCxEhb3vUhsw6l0uZXerZ8vgCZ.jpg

Product Overview

This equipment integrates multiple functions, including vapor and gas adsorption-desorption isotherms and rate tests under vacuum and dynamic gravimetric methods, temperature-programmed degassing (TPD), temperature-programmed reduction (TPR), temperature-programmed oxidation (TPO), etc. It is suitable for various scientific research needs such as adsorption kinetics, specific surface area, mesopore and micropore analysis. Equipped with high-precision temperature control, imported microbalance and dual-pump vacuum system to ensure testing accuracy and efficiency. It is suitable for corrosive gas adsorption research and supports fully automatic cycle adsorption testing, effectively improving scientific research efficiency.

Send an inquiry

Product Categories