Sunny Hengping GC1290/MS8100 gas chromatograph-mass spectrometer
Core Specifications
Product Details
GC1290/MS8100Gas chromatography mass spectrometer, which combines a single quadrupole mass spectrometer with a GC1290 gas chromatograph to provide customers with reliable analysis functions and working performance. Multi-core parallel processing technology can quickly obtain qualitative and quantitative information of each component in complex samples under high-speed scanning, improve analysis efficiency, and achieve rapid GC/MS analysis.
Advantages of mass spectrometry technology:
The quadrupole used in the MS8100 mass spectrometer is a long rod structure specially designed for high-performance analysis. It has excellent resolution and mass axis stability, and provides maximum ion transmission efficiency. The latest processing technology results from special research on the development of major national scientific instruments and equipment are adopted, combined with global optimization and processing selection, to ensure the accuracy of each set of four-level rods.
The homologous standard requirements for optimal processing of the quadrupole and vacuum chamber ensure the consistency and stability of the quadrupole mass spectrum.
Compared with flat plate repellers, the innovatively designed curved surface repeller has better electric field distribution and smoothness, improves ion generation efficiency and migration efficiency, and achieves better sensitivity and stability.
The detector has high resolution and long-term stability over the entire mass range (mass up to 1100u).

Gas chromatography separation system
GC1290/MS8100 Gas chromatography mass spectrometerEquipped with a GC1290 gas chromatograph, it adopts advanced EPC electronic gas circuit control and high-precision temperature control, combined with an optimized column oven and injector, to provide a chromatographic separation system with excellent performance and elevate GC/MS to a new level.
The integrated EPC module controls flow and pressure accurately and stably, and digitally controls the gas path parameters of the separation system, ensuring the consistency and reproducibility of analysis results.

Figure 1 Example of VOC standard sample spectrum repeatability test
Data acquisition and processing system
The MS8100 mass spectrometer uses a high-speed electronic circuit design, which significantly improves the data transmission speed. The scanning speed reaches 24000u/sec, making it possible to scan the entire range in GC-MS detection without sacrificing the analytical performance of the instrument, making customer applications more convenient.
Full-featured customized Clarity software fully supports GLP/FDA-21CFR Part11 electronic signature certification, making the operation more friendly and simple. The all-Chinese workstation software adopts task and method modes to provide flexible and changeable combinations, suitable for various workflows and applications. The graphical interface and good human-computer dialogue method make it easy to learn and master, and non-professionals can quickly master the use of the software. Supports CTC diversified sampling platform software reverse control function.
Application examples:

Figure 2 Example of 22 VOC standard sample spectra in indoor air (GB/T 18883-2022 "Indoor Air Quality Standard")
1. n-hexane, 2. ethyl acetate, 3. chloroform, 4. benzene, 5. carbon tetrachloride, 6. cyclohexane, 7. n-heptane, 8. trichlorethylene, 9. methylcyclohexane, 10. toluene, 11. n-octane, 12. tetrachlorethylene , 13. Butyl acetate, 14. Chlorobenzene, 15. Ethylbenzene, 16. Meta-xylene, 17. Para-xylene, 18. Styrene, 19. Ortho-xylene, 20. n-nonane, 21. 1,4-dichlorobenzene, 22. n-hexadecane

Figure 3Examples of standard sample spectra of 16 plasticizers (used in electronic appliances, food, paint, clothing, toys and cosmetics industries)

Figure 4European UnionRoHS2.0Examples of chromatograms for decabromodiphenyl and decabromodiphenyl ether standard samples in the directive

Figure 5 Example of VOC standard sample spectrum in water quality testing
Shanghai Mass Spectrometry Instrument Engineering Technology ResearchThe center was established with the approval of the Shanghai Municipal Science and Technology Commission and relies on Shanghai Sunny Hengping Scientific Instrument Co., Ltd. As an independently operated research unit under the company, it conducts development and research on mass spectrometry instrument technology, manufacturing processes and application methods. The research and development conducted by the Mass Spectrometry Engineering Center is guided by market demand, and industrialization is achieved through engineering technology development. The results are serialized and systematized through application technology development, focusing on meeting customer requirements and completing the close integration of market and technology.
Mass Spectrometry Engineering Center Honors & Achievements:
1. In 2019, the Mass Spectrometry Engineering Center was rated as an “Excellent Unit” by the Shanghai Science and Technology Commission;
2. Draft "GB/T 33864-2017 General Specifications for Mass Spectrometers" and implement it on February 1, 2018;
3. The process gas mass spectrometer won the "Beijing BCEIA" gold medal;
4. Gas chromatography mass spectrometerWon the "Beijing BCEIA" Gold Award;
Send Inquiry
Similar Instruments