Tianlong Technology Nucleic Acid Extraction GeneMix Pro Sample Processing System
Core Specifications
Product Details
Tianlong Technology's nucleic acid extraction GeneMix Pro sample processing system can complete 96 sample tube information entry, sample mixing, proteinase K/internal reference addition, cap opening/closing, sample transfer, deep well plate information entry, sample tube recovery to the sample rack, and loading the sample into the deep well plate within 16 minutes. Full automation liberates you from tedious mechanical operations, effectively improves work efficiency, saves manpower, ensures personnel safety, and creates new power for medical and health intelligence.
- Full automation
- Super compatibility
- Eight major measures to ensure safety
- 2023 "American IDEA Industrial Design Award"
| Instrument model | GeneMix Pro |
| Maximum flux | 96 |
| running time | 96 samples less than or equal to 20 minutes |
| Main functions | 1. Automatic switch cover (two sets of independent high-torque switch cover components, four sets of sampling tube clamping components) 2. Sample transfer and dispensing 3. PK/IC reagent loading 4. Automatic mixing of sample tubes 5. Automatic information system, “sample-result” whole-process information identification and transmission 6. Complete machine pollution prevention and control system 7. Automatic fault handling system |
| Adapted to sampling tube specifications | Diameter: 13-26mm; Height: 54-115mm Compatible with 5-20mL screw cap sample collection tubes; supports single tube, including swab 5 mix 1, 10 mix 1, 20 mix 1 sampling tubes directly on the machine The original tubes can be loaded into the machine with caps, and swab-containing samples can be loaded into the machine. The instrument is preset with a variety of conventional sampling tube specification programs, and customers can call or add sampling tube parameters. |
| Suitable for deep well plate specifications | 6×16T standard 1mL deep well plate 1×96T standard 1mL deep well plate Compatible with 3mL deep well plate; 3×8T 3mL large system deep well plate (Tianlong) The instrument is preset with a variety of deep well plate specifications, and customers can call or add specifications. |
| Pipetting function | The distance between two independent pipetting modules and pipetting pumps is adjustable, allowing deep well plates to be loaded with samples sequentially and well by well. Pipetting range: 5 -1000μL Pneumatic liquid level detection function Pipetting volume detection function, suction and discharge liquid following function |
| Pipetting accuracy | 5μL~50μL: Er≤3.5% 50μL~200μL: Er≤2.5% ≥200μL: Er≤2.0% |
| Pipetting precision | 5μL~50μL: CV≤2.5% 50μL~200μL: CV≤1.5% ≥200μL: CV≤1.0% |
| automatic information system | Sampling tube information scanning (one-dimensional code & two-dimensional code) Deep well plate status recognition (open system)/information scanning (Tianlong system) Automatic barcode scanning of sample racks "Sample-sample rack-deep well plate-PCR" information association, sample information-result information closed-loop management LIS system connection |
| Whole machine pollution prevention and control system | Independent UV disinfection function for experimental cabin and waste cabin Independent waste tank to isolate waste pollution Negative pressure function, 5pa negative pressure value HEPA filtration, filtration efficiency 99.999% at 0.3μm Droplet capture function |
| Mechanical precision motion control | High-precision encoder feedback ensures accurate mechanical operation Real-time motion monitoring and automatic processing |
| Automatic troubleshooting system | Fault information warning & operation prompts Switch cover monitoring and abnormality handling, the machine will not shut down if the switch cover is abnormal Barcode exception handling without downtime Pipetting detection exception handling system Sample tube transfer exception handling |
| touchscreen | 12.1-inch LCD touch screen |
| USB port | USB 3.0 |
| Network port | Network port |
| size | 1130mm(L)×780mm(W)× 920mm(H) |
| net weight | 200kg |
| power supply | Voltage: 100 ~ 240 V; Frequency: 50/60HZ; Rated power: 600VA |
| temperature | 15℃-35℃ |
| relative humidity | 35%RH~70%RH, no condensation |