BSD-VVS&DVS multi-station gravimetric gas vapor adsorption instrument
Core Specifications
Product Details
Main Function / Main Function
◆ Vacuum gravimetric vapor adsorption and desorption isotherm (VVS);
◆ Vacuum gravimetric vapor isobaric adsorption and desorption rate (VVS);
◆ Vacuum gravimetric gas adsorption and desorption isotherm (VGS);
◆ Vacuum gravimetric gas isobaric adsorption and desorption rate (VGS);
◆ Vacuum gravimetric temperature programmed degassing (TPD);
◆ Dynamic gravimetric vapor isobaric adsorption and desorption rate (DVS);
◆ Dynamic gravimetric vapor isobaric adsorption and desorption rate (DVS);
◆ Dynamic gravimetric gas adsorption-desorption isotherm (DGS);
◆ Dynamic gravimetric gas isobaric adsorption and desorption rate (DGS);
◆ Dynamic gravimetric temperature programmed desorption (TPD);
◆ Dynamic gravimetric temperature programmed reduction (TPR);
◆ Dynamic gravimetric temperature programmed oxidation (TPO);
◆ Evaluation of multi-component competitive adsorption by dynamic gravimetric method;
◆ Distillation and purification of reagents;
◆ Vacuum thermogravimetric: Vacuum thermogravimetric analysis can be performed;
◆ Can be upgraded to adsorb corrosive vapors and gases (such as SO2, H2S, NH3, etc.);
Report Content / Report Content
◆ Vacuum degassing thermogravimetric report
◆ Adsorption and desorption isotherm
◆ Adsorption and desorption speed
◆ BET single point method specific surface
◆ Langmuir specific surface
◆ Mesopore analysis by BJH method
◆ T-plot micropore analysis
◆ D-R method micropore analysis
◆ HK method micropore analysis
Performance Parameters / Performance Parameters
test function | adsorption-desorption isotherm, adsorption kinetics and other adsorption performance tests | |
constant voltageAdsorption kinetics | Constant pressure adsorption kinetic analysis (constantPressure adsorption and desorption rate) | |
Number of analysis bits | Optional4or8analysis bits; Simultaneous analysis of multiple analysis positions, aiming at the slow constant pressure adsorption rate and low adsorption test efficiency of the gravimetric method,substantially improvedTest efficiency and accelerate scientific research progress; The analysis environment of multiple analysis positions is completely consistent, and the subtle adsorption performance differences of the same batch of materials can be known; | |
Microbalance resolution/range | Original imported industrial microbalance,1ug/5000mg(0.1ug/500mgOptional); Compared with similar products, the measuring range is improved2-5times,Broaden the range of sample loading and increase sampling representativeness,Improve accuracy; | |
Test gas type | water vapor, organic vapor, andCO2, alkanes and olefins and other non-corrosive gases; | |
Is it optional?NH3,SO2wait corrosionsexual gasadsorbate | yes | |
Fully automatic cycle adsorption test (recommended configuration) | Fully automatic constant pressure temperature swing adsorption and desorption Fully automatic constant temperature pressure swing adsorption and desorption Fully automatic temperature and pressure swing adsorption and desorption Fully automatic cycle adsorption and desorption life evaluation | |
Degassing furnace and constant temperature bath switching method (recommended configuration) | Fully automatic switching Especially for fully automatic cycle adsorption life evaluation | |
AdsorptionTest temperature | thermostatic bath,-5℃~150℃, precision±0.1℃; | |
steamAnti-condensation | The gas circuit system is fully constant temperature.Room temperature~60℃, precision0.1℃; | |
Steam generation method | "Static evaporation" method | “Carrier gas mix”flowLaw |
steam"Humidity/Partial Pressure" control range | 0.1%~98% P/P0 | 2%~98% P/P0 ,lowerP/P0 Optional |
Reagent tube liquid reagent capacity | 120ml | 120ml Patented reagent saturated condensation recovery technology improves reagent utilization and reduces reagent consumption |
degassingactivationpreprocessing | Vacuum degassing, recommend molecular pump high vacuum degassing function Room temperature~400℃, precision±0.1℃; | Normal pressure purge degassing Room temperature~300℃, precision±0.1℃; |
Visualized programmed heating and degassing | 32Programmed temperature rise in stages to prevent samples from flying; The constant weight process of the sample can be visualized in real time to accurately determine whether the sample is completely degassed; | |
buoyancyCorrection | Mode 1: Buoyancy calculation mode(default); Mode 2: Blank buoyancy background subtraction mode; modelthree: Background subtraction curve mode; | |
Blank bit synchronization test | Supports blank bits as background and buoyancy deduction for simultaneous testing; Eliminate systematic errors,SubstantiallyImprove test accuracyand stability; | |
Remove steamvacuumsystem | Yes, dual pump vacuum system High vacuum mechanical pump+Steamgaspump The steam pump has a program-controlled steam removal function | |
Molecular pump high vacuum system (recommended configuration) | Original imported molecular pump,Vacuum degree is better than10E-6 torr Can significantly reduce vapor background residue and improve test accuracy | |
Segmented pressure measurement | Dual pressure sensorsegmental testing; Original imported capacitive film pressure sensor; | |
Air controlled high vacuum damper valve | Original imported air-controlled high vacuum baffle valve; Large diameter, air control and zero heat generation; | |
mass flow controller | Imported high-precision mass flow controllerMFC Achieve precise gas and vapor concentration control | |
Test Report/Data Report