Core Specifications

Instrument type
Specific surface and pore size analyzer
Detection principle
Static method (static volume method)
Number of analysis stations
The number of analysis bits is optional: 3/6/9/12
Test range
Specific surface area is above 0.0005㎡/g, pore diameter is 0.35-500nm;
pressure range
10E-2Pa, with optional molecular pump, the vacuum degree can reach 10E-8Pa;
test theory
static method
Repeatability
≤1%
Applications
Chemicals & PetrochemicalsEnergy & UtilitiesPharmaceuticals / Biopharmaceuticals

Product Details

                                                                                                           BSD-660 Series Physical Adsorption Instrument Selection Guide

Instrument model

BSD-660S

BSD-660M

BSD-660MG

BSD-660MC

BSD-660MV

Instrument name

Specific surface area and

Pore ​​size analyzer

High performance specific surface area and

Micropore Analyzer

High performance gas adsorption and

Micropore Analyzer

High performance corrosive gas adsorption and

Micropore Analyzer

High performance gas vapor adsorption and

Micropore Analyzer

Main functions

BET specific surface area analysis,

Mesoporous pore volume and pore size analysis.

In addition to the 660S functions,

With micropore volume and pore size analysis

Structure and function.

In addition to the 660M function,

Capable of adsorption analysis of various gases (non-corrosive)

Structure and function.

In addition to the 660MG function,

Capable of corrosive gas adsorption analysis

Knotstructure and function.

In addition to the 660MG function,

With vapor adsorption analysis

Structure and function.

Commonly tested materials

Non-porous materials, such as lithium battery materials,

Inorganic salts, oxides,

Hydroxide, metal powder, organic materials, etc.

Porous materials, such as zeolite molecular sieves, activated carbon,MOF、COF、HOF, porous carbon, silica gel, etc.


Main functions:


◆ Full function: specific surface area, mesopore, micropore, ultramicropore analysis;

◆ High-throughput: The number of analysis bits is optional: 3/6/9/12;

◆ Fully automatic: degassing → test, fully automatic switching;

◆ High configuration: Optional dual-station dual molecular pump set, molecular pump degassing;

◆ Anti-pollution: "Pressure-controlled heating" of microporous samples prevents pollution and degassing;

◆ Zero helium pollution: Helium temperature measurement area first, then automatic degassing;

◆ Automatic cycle: automatic evaluation of material cycle adsorption performance;

◆ Conventional gas adsorption: such as N2, O2, Ar, CO, CO2;

◆ Combustible gas adsorption: such as H2, CH4, C2H6 and other alkanes and alkynes;


Optional Function Optional Function


+ constant temperature water bath

Achieve non-corrosive gas adsorption at any temperature between -10-80℃


+Liquid nitrogen level constant device LNT

Realize non-corrosive gas adsorption measurement at any temperature from 100K to room temperature


Technical parameters:


◆ Wide testing range: specific surface area 0.0005㎡/g or more, pore diameter 0.35-500nm;

◆ Testing efficiency: multi-point BET (excluding degassing process), standard mode 12 samples/60min; extreme speed test mode 12 samples/15min;

◆ High testing accuracy: specific surface area, pore diameter, pore volume, adsorption capacity, quantitative error <0.5% RSD (based on BET value of standard sample);

◆ Programmed temperature rise and degassing: software controls program temperature rise, room temperature -400℃, accuracy better than 0.1℃;

◆ Intelligent degassing completion judgment: supports automatic software judgment and automatically judges the degassing effect according to pressure changes;

◆ Prevent flying and degassing: "Programmed pressure control" + "Programmed temperature control" + "Degassing furnace lift" = "Pressure controlled temperature rise";

◆ Vacuum degree: the vacuum degree can reach 10-9Pa; try


Feature structure:

EDQAutrIAvZtazNXkXtL75kqpPK1lXrXyf1KxcPM.png

Technical advantages:


◆ High throughput and high efficiency: supports the analysis of up to 12 samples at a time;

◆ True full automation: The world's first degassing furnace and Dewar cup automatically switch, no need to manually transfer sample tubes or degassing furnace;

Patent name: Fully automatic physical adsorption instrument that automatically switches the positions of the heating furnace and constant temperature bath cup. Patent number: ZL202020232044.8;

◆ High time utilization: It solves the waste of time when conventional instruments cannot start testing after degassing is completed after get off work, making it a reality to install samples after get off work and read data at work;

◆ Completely eliminate "helium pollution": Helium test dead volume → vacuum heating degassing → adsorption test. It is the first in the world to solve the problem of helium pollution in micropore analysis and improve test accuracy;

◆ Anti-flying and degassing: Supports "programmed pressure control" + "programmed temperature control" degassing, and automatically raises and lowers the degassing furnace according to pressure changes to prevent samples from flying;

Patent name: Physical adsorption instrument with programmable pressure-controlled anti-flying and degassing system Patent number: ZL202020230457.2;

◆ Support automatic cycle test: automatic degassing + test cycle test, used to evaluate material adsorption performance stability and adsorption performance lifespan evaluation;

"Pressure controlled temperature rise" anti-flying and degassing technology

That is, the programmed temperature rise technology controlled by gas pressure automatically starts and stops the program temperature rise according to pressure changes, fundamentally preventing the sample from flying;

Patent name: Physical adsorption instrument with programmable pressure control and anti-flying degassing system Patent number: ZL202020230457.2



PXwNJ9hOGfLbDYXXZ352heHgQ4xgNP3wVEiloNHn.png

"Automatic constant temperature zone" patented technology


The curve shows that the change rates of the "equivalent volume of the adsorption chamber" in the 24-hour temperature zone constant effect of the three methods are: BSD temperature zone servo automatic constant: 0.10%, isothermal clamp: 0.25%, liquid level sensor: 0.55%


U3lmTZivRhKLzJCvgtG7WPvNBLtq30gLjkX3B0Pu.png

    

Patent name: Physical adsorption instrument with automatic constant structure in temperature zone Patent number: ZL2018 2 0401132.9

◆ Convenient installation and sealing: One-time sealing technology for 6 sample tubes in a single analysis station, no need to seal each tube one by one, unparalleled efficiency experience;

Patent name: A physical adsorption instrument with dense multi-sample tubes and sealed test tube jackets Patent number: ZL 2019 2 1078195.6;

◆ The gas circuit system is fully constant temperature: the internal gas circuit system of the instrument is fully constant temperature to 40℃, with an accuracy better than ±0.01℃;

◆ Sliding door: humanized and easy to open and close, saving laboratory space;

Patent name: Physical adsorption instrument with upper and lower opening and closing protective covers Patent number: ZL202022203243.9;

◆ Electric turbine liquid nitrogen pump: humanized liquid nitrogen addition, stepless speed regulation, free movement, safe and convenient, liquid nitrogen pollution-free;

Patent name: An electric liquid nitrogen pump with impeller structure (non-pneumatic) Patent number: ZL 2017 2 0864873.6;

◆ High reliability: International supplier system, core components are imported with original packaging;

◆ Open data interface: The software can be used in conjunction with Lims to upload test results to Lims;


Comparison test:

fY5hoYb5vESVW0oK1Aqp4E1T0UTRmjpCZGoLc1FW.jpg


Test report:

cKIecdl3Hv06FVDi4oDpU9jOvUhbpjOPhWOsepG3.jpg



5ZBzeKynHPvYzRzx0HAHb2eRjIllvRLkGbfXO3DJ.jpg


Awards received:

1.3i Award - Outstanding New Products in the Scientific Instrument Industry in 2022

Redefining full automation - Best Instruments BSD-660 specific surface area and pore size analyzer, winner of the Outstanding New Product Award

2. Won the fifth "Good domestic instruments"Awards

What users say is good is really good! Best's BSD-660 fully automatic high-throughput specific surface area and pore size analyzer was rated as "Good Domestic Instrument"


Related information:

Related standards:
1.GB/T 19587-2017 Method for determination of specific surface area of ​​solid substances using gas adsorption BET principle; ISO 9277-2010 Determination of specific surface area of ​​solid substances using gas adsorption BET method
2. GBT 39713-2020 Fine ceramics - Ceramic powder specific surface area test method BET method
3. GB/T 21650.1-2008/ISO 15901-1:2005 Determination of pore size distribution and porosity of solid materials by mercury intrusion method and gas adsorption method - Part 1: Mercury intrusion method
4. GB/T 21650.2-2008/ISO 15901-2:2006 Determination of pore size distribution and porosity of solid materials by mercury porosimetry and gas adsorption method - Part 2: Analysis of mesopores and macropores by gas adsorption method
5. GB/T 21650.3-2011/ISO 15901-3:2007 Determination of pore size distribution and porosity of solid materials by mercury porosimetry and gas adsorption method - Part 3: Analysis of micropores by gas adsorption method
6. GBT13390-2008 Determination of specific surface area of ​​metal powders Nitrogen adsorption method
7. GBT 10722-2014 Carbon black Determination of total surface area and external surface area Nitrogen adsorption method
8. GBT 7702.20-2008-Test method for coal-based granular activated carbon. Determination of pore volume and specific surface area.
9. GB/T 6609.35-2009-Methods for chemical analysis and physical properties of alumina Part 35: Determination of specific surface area Nitrogen adsorption method