e-BLOT Touch Imager electronic tablet imager
Touch Imager is the first contact imager based on the electronic tablet imaging technology pioneered by e-BLOT. Western Blot Chemiluminescence imaging equipment designed for molecular biology laboratories. This instrument achieves high sensitivity and wide dynamic range protein band detection by eliminating the loss of light signals caused by traditional optical lenses, and is suitable for quantitative analysis of protein expression in scientific research experiments.

Technical background and advantages
Western blot is a commonly used technique in protein expression studies. Traditional imaging methods include DAB color development, darkroom pressing, and cold CCD imaging. DAB color development is rarely used due to its limited sensitivity and quantitative range; darkroom pressing has a narrow quantitative range, making it difficult to meet precise quantitative requirements; cold CCD imaging is limited by lens loss, imaging distance and chip size, and its sensitivity is often lower than expected, and it is difficult to simultaneously collect strong and weak signals. Fluorescence imaging is susceptible to membrane background interference and is less sensitive than chemiluminescence. e-BLOT Touch Imager uses contact chemiluminescence imaging technology, which effectively reduces the loss of light signals during transmission by directly contacting the photosensitive chip with the sample. This significantly improves imaging efficiency and quantitative accuracy while maintaining high sensitivity of chemiluminescence.
Features
1. Touch Imager uses NASA-grade super large photosensitive chip
Touch Imager applies a 168cm² (12cm × 14cm) photosensitive chip to Western Blot to improve imaging performance. The Touch Imager photosensitive chip area is more than 130 times larger than the traditional cold CCD chip area.
Excellent sensitivity performance
2. Touch Imager sensitivity is 2 orders of magnitude higher than cold CCD
Touch Imager electronic tablet imaging
Contact photosensitive, the signal collection distance is 0, the optical signal is lossless, it has high sensitivity and wide dynamic range, and the imaging speed is fast.
It takes into account the advantages of optical film and cold CCD imaging, and its performance is improved by orders of magnitude compared to the former two.

Optical film imaging method: the optical signal is lossless, but its imaging process is cumbersome and easy to cause pollution. At the same time, its signal collection ability is weak, time-consuming, has a narrow quantitative range, and is prone to overexposure.
Cold CCD imaging method: long optical path, optical signal loss of more than 99%; low sensitivity, narrow quantitative range,Easy to overexpose.
3. Touch Imager can image more than 95% of the samples in 1 second at extremely fast speed
The light transmittance of Touch Imager is more than 400 times that of cold CCD cameras.
The higher the light transmittance of the imaging system, the stronger the collection capability will be and the shorter the collection time will be.
because Touch ImagerThe special contact imaging method, the film and the chip are directly bonded, there is no loss of signal acquisition, the sensitivity of the imaging system is higher, and the image quality is better.


4. The quantitative range of Touch Imager is 2 orders of magnitude higher than that of cold CCD imaging.
Touch Imager's ultra-large electronic capacity enables accurate quantification over a wider range of signal strengths, presenting both strong and weak signals.

5. Touch Viewer is an efficient, fast and powerful software

Personalized account management:Users can create their own independent accounts without interfering with each other, ensuring data security and easy search.
Raw data export:Supports original image export in two formats, 16 bit TIF format (for accurate quantitative analysis) and .ebt format (for saving and modifying image editing information).
The heat map shows:No need for grayscale value analysis, protein expression can be displayed through different colors.
One-click imaging:No condition optimization is required, ideal results can be collected with one click, and images are saved automatically after completion, eliminating the need for secondary operations.
Export at specified resolution:300 dpi, 600 dpi, 1200 dpi or specified resolution (72~1200 dpi) output image, directly used for article publication.
Integrated operation:There is no need to switch interfaces, and the same interface can be used to complete image adjustment, editing, annotation, cutting, grayscale value analysis, result export, report generation and other operations at the same time.
Application areas
Western Blot: Western Blot Chemiluminescence Imaging, Quantitative Analysis
Nucleic acid blotting: Southern Blot, Northern Blot chemiluminescence imaging analysis
Dot Blot: Dot Blot Chemiluminescence Imaging and Quantification
Isotope imaging: low-cost isotope direct imaging (no phosphor screen required)
Protein gel imaging: Coomassie brilliant blue staining, silver staining gel imaging
Color Marker Imaging: Exclusive Marker Mode
Honors and intellectual property rights

Industry and Design Awards
Design Category: German Red Dot Design Award
Instrument industry awards: Instrument and Testing 3i Award, Annual Scientific Instrument Industry Outstanding New Product Award, Magnolia Cup Best Technology Innovation Award
Innovation and Entrepreneurship Competition:
Second Prize in the Finals of the 3rd China Medical Device Innovation and Entrepreneurship Competition
"Maker China" Third Prize in the Finals of Shanghai Small and Medium Enterprise Innovation and Entrepreneurship Competition (First Place in Biology Category)
Winning Prize of the 8th China Returnee Entrepreneurship Competition
Winning Enterprise of the 10th China Innovation and Entrepreneurship Competition National Competition
Supporting enterprise qualifications: Shanghai Specialized and New Small and Medium-sized Enterprises, Shanghai High-tech Enterprises, Shanghai's Top 50 Enterprises with the Most Investment Potential
Patent reserve
6 invention patents, 5 PCT invention patents, 4 utility model patents
Core invention patent number: ZL 2019 1 0244792.X
Compliance certification
CE, RoHS, ISO9001, RCM, VCCI, KC certification
Ability to use and support customers on the ground
User scale:Used by 1000+ laboratories around the world, helping customers publish 800+ high-level papers (including high-IF journals such as Nature, Signal Transduction and Targeted Therapy, Cell Discovery, etc.)
Customer coverage:Domestic 985/211 universities, institutes of the Chinese Academy of Sciences, and top-level hospitals; overseas well-known universities, pharmaceutical companies, and cancer research centers in Europe, the United States, Japan, South Korea, and Southeast Asia
Global service network:The e-BLOT sales network has spread to more than 20 countries and regions around the world, including China, South Korea, Singapore, Japan, the United States, Canada, Switzerland, Germany, Sweden, the Netherlands, Belgium, Luxembourg, Russia, the Czech Republic, Slovakia, Hungary, Romania, Bulgaria, Croatia, Slovenia, Greece, Poland, etc. With the establishment of after-sales service centers in various countries, e-BLOT can provide timely and reliable after-sales services to customers around the world.