Bettersize3000Plus laser/image particle size and shape analyzer
Core Specifications
Product Details
Product introduction
Bettersize3000Plus laser/image particle size and shape analyzer is a laser + image two-in-one particle size and shape analysis system. Its laser scattering system is a dual-lens oblique incidence optical system, and its imaging system is a dynamic dual-channel telecentric microscope imaging system, which can simultaneously conduct particle size and particle shape analysis, achieving dual uses in one machine.

The dual-lens oblique incidence optical system is composed of a high-power pump polarization laser, an imported lens set, a quartz sample cell and a full-angle photodetector array. Due to the use of high-performance lenses and a unique laser oblique incidence structure, full-angle scattered light signal reception is achieved under single beam conditions - this is Baxter's original patented technology. This technology not only achieves the effect of using multi-beam technology to expand the scattered light angle of imported instruments, but also avoids the connection deviation of intermittent scattered light signals caused by multi-beam technology and the sample refractive index deviation caused by multi-wavelength, making the test results more accurate, and at the same time achieving accurate particle size testing of nanometer, micrometer and even millimeter-level samples. Due to the large number of detectors and unique structure, the instrument has a strong ability to resolve single-peak, double-peak and multi-peak samples. At the same time, the instrument also has sample refractive index measurement technology, automatic centering technology, anti-dry burning ultrasonic dispersion technology, SOP technology, high-power short-wavelength polarized light technology, etc., further ensuring repeatability, accuracy and resolution.
The dynamic dual-channel telecentric microscope imaging system is connected in parallel to the laser scattering system, which can capture images of particles in flow at any time and perform particle shape analysis at the same time. While obtaining the particle size distribution, it can also obtain particle shape parameters such as circularity, aspect ratio, and roughness at the same time. More importantly, this microscopic imaging system can accurately capture the largest particles in the sample, achieve effective measurement of D100, make up for the shortcoming of the laser particle size analyzer that cannot test D100, and provide a reliable method for accurately testing D100 in lithium batteries and other fields.part.
Bettersize3000Plus laser/image particle size and shape analyzer is also exported in batches to more than a dozen countries and regions including the United States, Germany, Brazil, South Korea, and Russia. In the second half of 2019, Bettersize3000Plus participated in the inter-laboratory comparison test event "Determination of Ceramic Powder Particle Size by Laser Scattering Method" organized by the German Federal Institute for Materials Research and Testing. In the PK with international brand instruments submitted for inspection by 43 laboratories, the test results of all samples of Bettersize3000Plus were within the allowable tolerance range, ranking first in the group with a 100% comparative test success rate, and attracting the attention of the European particle industry.

Bettersize3000Plus laser/image particle size and shape analyzer also has refractive index measurement technology, automatic testing technology, automatic water inflow, automatic drainage, automatic bubble elimination, automatic cleaning technology, particle image rapid identification technology, sample compounding technology, etc. Its comprehensive performance reaches or exceeds the level of imported instruments, and is especially suitable for laboratories such as large enterprises, universities, and research institutes.
Basic performance indicators
| Test range | 0.01-3500μm (can measure D100) |
| Measurement principle | Mie scattering theory (default), Fisher diffraction theory (optional), dynamic images |
| Accuracy and Repeatability Error | ≤0.5% (national or international standard sample D50 deviation) |
| Accuracy Calibration | Yes, this function ensures the accuracy of the instrument |
| Bimodal resolution | Class A (JJF1211-2008, JJG167-2020), with multi-peak resolution capability |
| Laser light source | High-power polarization-pumped fiber solid-state laser (short wavelength) |
| Photodetector | 96 (forward, side and rear) |
| Optical system | Dual-lens oblique incidence optical system (patented technology) |
| Refractive index measurement | Yes, it can measure the refractive index of samples (patented technology) |
| Wet dispersion system | |
| Imaging system | Dual high-speed cameras, dual-channel optical imaging system |
| Measurement mode | One-button mode (SOP)/manual mode/automatic sample addition mode/laser + dynamic image mode/dynamic image mode |
| Fastest single test time | ≤1S |
| Data security | FDA 21 CFR PART 11 |
| Related Pharmacopoeia | USP429 / EP2.9.38 / Chinese Pharmacopoeia 0982 |
| Related standards | ISO 13320-2020,GB / T 19077-2024,GB/T 41949-2022 |
| power supply | 100-240VAC,50/60Hz,2.5A |
Application areas
●Various non-metallic powders: such as heavy calcium, light calcium, talc powder, kaolin, graphite, wollastonite, brucite, barite, mica powder, bentonite, diatomaceous earth, clay, silicon dioxide, garnet, zirconium silicate, zirconium oxide, magnesium oxide, zinc oxide, etc.
●Various metal powders: such as aluminum powder, zinc powder, molybdenum powder, tungsten powder, magnesium powder, copper powder, rare earth metal powder, alloy powder, etc.
●Other powders: river sediment, lithium battery materials, catalysts, phosphors, cement, abrasives, medicines, pesticides, food, coatings, dyes, ceramic raw materials, chemical materials, nanomaterials, papermaking filler coatings, various emulsions, etc.
Outstanding features
●Oblique incidence dual-lens technology: Baxter's patented technology uses laser oblique incidence technology and combines forward, side and back scattered light detection technology to achieve full-angle measurement, expand the measurement range, improve the measurement accuracy of fine particles, and improve the resolution.
●Microscopic image and laser scattering two-in-one technology: The laser method has advantages in testing fine particles, while the image method has high accuracy in testing coarse particles. The combined testing of laser and image is a strong combination, with higher accuracy of test results and particle shape analysis.
●Sample refractive index testing technology: For samples with unknown refractive index, the refractive index can be measured first, including the real part and the imaginary part, to ensure the accuracy of particle size testing.
●Automatic circulation dispersion and automatic testing technology: anti-dry burning ultrasonic disperser, centrifugal circulation pump, automatic water inlet system, automatic drainage and overflow system, applicable to all samples, ensuring sufficient sample dispersion and ensuring test accuracy and repeatability.
good repeatability