Instrument.com.cn Jul 20, 2026

Boiler water and cooling watermiddleironElement contentDetermination of

Preface

In modern industrial production, the stable operation of boilers and cooling water systems directly affects equipment safety, energy efficiency and lifespan. Monitoring iron levels in water is a key step in assessing water quality and preventing corrosion and scaling. Iron ions may come from pipe corrosion, water contamination orCraftsmanshipImproper handling, overdoseaccumulationIt will reduce heat transfer efficiency, induce local corrosion and accelerate equipment wear. Therefore, accurate determination of iron content is of great significance to ensure system safety and optimize water quality management.This study is based on the standard "GB/T 14427-2017 Boiler water and cooling water analysis methods Determination of iron》,PickuseA500Zeeman atomic absorption spectrometer, taking advantage of its excellent background suppression ability and excellent stability,rightBoiler water and cooling watermiddleironElement contentPerform method validation.

Experimental conditions

• Instrument reagents

instrument:A500Zeemangraphite furnaceatomic absorption spectrophotometer

Reagents:Nitreacid

standard material:GBW(E)084937 Iron single element solution standard material

• Instrument parameters

Instrumental analysis conditions for graphite furnace method

wavelength(nm)

248.33

Spectral bandwidth (nm)

0.1

Negative high pressure (V)

427.75

Element lamp current (mA)

4.0

Button background method

Zeeman buckle background

Sample injection volume (μL)

30


Temperature rising program of graphite furnace method

step

temperature(℃)

Heating time (S)

hold time (S)

Internal air flow

1

120

10

30

big

2

150

10

5

big

3

2300

0

3

close

4

2400

0

2

big


Data results

• standard curve

 

• Quantification limit

Number of measurements

1

2

3

4

5

6

Absorbance

0.00283

0.00237

0.00278

0.00066

0.00368

0.00008

Number of measurements

7

8

9

10

11


Absorbance

0.00164

0.00237

0.00223

0.00246

0.00442


Standard deviation S of absorbance measured 11 times0

0.001117

standard curve equation

A=0.042586C-0.002506

Correlation coefficient

0.99979

Limit of quantitation (μg/L)

0.262

• Precision

Number of measurements

1

2

3

4

Absorbance

0.15599

0.15658

0.15922

0.15839

Number of measurements

5

6

7


Absorbance

0.15835

0.15892

0.16059


Absorbance average

0.15829

RSD/%

0.97


in conclusion

based onA500Zeeman atomic absorption spectrophotometersuperioranalyze performance,This studyEstablisheda measureBoiler water and cooling watermiddleironElement contentreliablemethod. The instrument uses Zeeman background correction technology and real-time dual-beam optical path design, which significantly improves the stability and accuracy of detection and ensuresironReliable determination of elements.The quantitative limit of this method can reach0.262μg/L,Relative standard deviation (RSD)for0.97%,It fully reflects the high sensitivity and good repeatability of the instrument and is suitable for iron content in actual water samples.elementcontentof semenallowanalyze.