CIS-JH-4.0 Joule heating device, millisecond level temperature rise 1000-3000℃
Core Specifications
Product Details
The Joule heating device is a new type of rapid heat treatment/synthesis equipment. This equipment can make the material reach the temperature (1000~3000°C) in a very short time (millisecond/second level), and the heating rate can reach the fastest 10000k/s; by extremely rapid heating of the material, the physical property changes of the material in extreme environments and severe thermal shocks can be investigated, and nanoscale particles, single-atom catalysts, high-entropy alloys, etc. can be prepared through extremely rapid temperature rise and cooling.

Application fields of Joule heating devices:
1. Nanomaterial synthesis (such as high-entropy oxides, alloy nanoparticles);
2. Development of energy materials (electrode materials such as lithium-ion batteries, sodium-ion batteries, zinc-iodine batteries, etc.);
3. Electrocatalysis and photocatalysis (electrolysis of water for hydrogen production, CO₂ reduction, nitrogen fixation, etc.);
4. Waste recycling (recycling of valuable metals in waste lithium batteries and waste anode graphite);
5. Preparation of ultra-high temperature materials (ceramics, high-entropy alloys, etc.);
6. Rapid heat treatment (RTP): material surface modification, phase change research, etc.
......
Product parameters of Joule heating device:
Version: flagship model;
Power supply: three-phase 380V/40A;
Output voltage: 0-40V;
Output current: 0-500A;
Current ramp time: 2ms;
Settable minimum pulse width: 1ms;
Settable count pulse: 255;
Data collection cycle: 5ms;
Data communication method: RS485+Ethernet+USB;
Data collection method: touch screen + PC;
Data control method: touch screen + software;
Data collection content: real-time temperature, real-time voltage, real-time current;
Clamping electrode: fixed;
Maximum temperature: 3000°C (sample stages vary in type, specification and particularity);
Long-term thermal insulation: long-term within 2000℃ (taking 100*20*1mm graphite plate as an example);
Control mode:Long-term constant temperature (2000℃, 18h), current flow control (unlimited second-level current shocks), 6-segment temperature slope mode (expandable), temperature thermal shock mode (timed interval/fixed temperature interval), S curve, sine wave curve;
Temperature measurement method: infrared temperature measurement;
Temperature measurement range: 250-2000℃/700-3200℃/550-3000℃ (imported);
Power cooling method: water cooling;
Vacuum chamber: made of 304 stainless steel, square, Φ16mm observation window, sapphire window, volume about 400ml, chamber with water cooling;
Air circuit device: 1 air intake, 1 vacuum, 1 exhaust;
Vacuum pump: Feiyue VRD-8 is standard, and the vacuum pump is controlled through the touch screen;
Standard sample stage material: flexible graphite paper, graphite plate, graphite tube, graphite boat, etc. (can also be adapted to other types of sample stages);
Sample stage size (can be customized): ≤100mm*15mm*0.2mm;
Sample test volume: 500mg (specific gravity 1);
Overall size (length, width and height): approximately 750mm*610mm*660mm (specifically subject to actual conditions).
Joule heating device installation example




.......