Zhetu UR4-50LB high temperature vacuum drying oven
Core Specifications
Product Details
High temperature vacuum drying oven
Product overview of Zhetu UR4-50LB high temperature vacuum drying oven
High-temperature vacuum drying oven (covering ordinary digital display and program-controlled configuration) is mainly used for material heat treatment, sample degassing, resin curing, component drying and other working conditions. The maximum operating temperature of the equipment can reach 600°C, and high-temperature operations can be completed in a negative pressure vacuum environment. The vacuum environment can effectively inhibit the oxidation reaction of the sample and prevent the material from being splashed by heat. The product line is divided into ordinary pointer models, -I digital display program models, and -II touch program models. Vacuum measurement adopts the first-generation mechanical pointer meter, the second-generation digital vacuum meter, and the third-generation integrated touch-control vacuum meter respectively. The whole machine supports the optional vacuum pump and pump protection condensation complete set of components, and is widely suitable for experimental research and development and small batch production in scientific research institutions, new material laboratories, electronics, chemical industry, industrial and mining enterprises.
Accurate temperature control
① Equipped with an optimized PID intelligent temperature control algorithm, the system collects temperature data in the cavity in real time, dynamically adjusts the heating output power, and alleviates the temperature overshoot phenomenon during the heating stage.
②The program-controlled version supports multi-stage process settings, and the heating rate, constant temperature duration, and cooling steps can be freely set. After the entire set of process settings is completed, the equipment will automatically run without the need for on-site personnel.
③ After leaving the factory, it has undergone multi-point temperature calibration, fully considering the temperature differences around the corners of the cavity and the shelves to ensure uniform temperature in the working area and meet experiments with high requirements for temperature consistency.
Vacuum protection
① The inner cavity of the box can form a closed negative pressure environment, isolating the oxygen component in the air, and reducing the possibility of sample oxidation and deterioration during high-temperature operations.
②The B series vacuum pump and condensation protection complete set can effectively condense and collect the solvent and water vapor emitted by the sample, reduce the direct entry of volatile substances into the vacuum pump, and extend the service life of the pump.
③ Vacuum testing provides three solutions: mechanical pointer, digital display, and touch collection. Different versions are adapted to different experimental needs such as visual reading, precise numerical recording, and integrated control.
Temperature resistant cavity
①The inner tank is made of high-temperature-resistant metal material, which can withstand long-term high-temperature cycle work, is not prone to deformation, and has good tolerance to some volatile reagents.
② The door sealing assembly is suitable for a wide temperature range. It maintains the sealing performance of the box under high temperature conditions, ensures stable vacuum in the chamber, and reduces experimental deviations caused by air leakage.
③The box is equipped with a multi-layer heat insulation structure to block the conduction of high temperature in the inner cavity to the outside, reduce the surface temperature of the equipment shell, and reduce the risk of burns caused by accidentally touching the operator.
Easy to use
① The instrument interface has a clear layout, clear functional divisions, and simple logic for setting parameters such as temperature, vacuum, and time. New operators can get started with the operation after simple familiarity.
② Built-in complete parameter memory function, ‑I and ‑II models can save multiple sets of commonly used experimental process parameters and directly retrieve them when repeating experiments, eliminating the tedious steps of repeatedly entering parameters.
③The control system provides multiple versions of pointer LCD, LCD button +I, and integrated touch screen-II. Different operating surfaces take into account the three requirements of cost-effectiveness, reading accuracy, and convenient operation.
Flexible configuration
① It has multiple temperature specifications of 400℃, 500℃, and 600℃, and three-speed instrument configurations of ordinary, -I, and -II, covering various process requirements from normal temperature to high temperature heat treatment.
②The pump set supports a variety of options. You can choose a vacuum pump with a condensation protection package, or you can choose a vacuum pump alone.
③ There is also a pumpless version to choose from, adapting to different budgets and working conditions where supporting equipment is already available on site.
Safe and reliable
① The box has a reserved pressure relief structure to complete the pressure relief when abnormal pressure occurs to avoid the risk of pressure in the cavity and ensure the on-site safety of the equipment and operators.
② Before each piece of equipment leaves the factory, it completes vacuum leak detection and high-temperature aging tests to check key indicators such as temperature control and sealing performance to reduce the probability of failure after the equipment is delivered.
③Integrate multiple safety protection logic. When the actual temperature exceeds the set threshold, the device will trigger over-temperature protection and cut off the heating output. -I and -II models come with audible and visual alarm prompts.
Ordinary pointer model
① Suitable for conventional drying scenarios with limited budget and no need to accurately read the vacuum value, but only need to determine the presence or absence of vacuum.
② Adopt the first generation circular mechanical pointer vacuum gauge, rely on the dial to visually read the vacuum status, and meet the requirements for basic vacuum drying.
③With the LCD fixed-value temperature program instrument, it can realize constant temperature or multi-stage program temperature control. The overall hardware is mature and stable, and maintenance is simple and convenient.
Type I digital display program/Type II integrated touch screen
Type I digital display program
① Suitable for material research and development and process exploration scenarios, R&D laboratories that need to accurately read and record vacuum values and pursue cost-effectiveness.
② Equipped with a second-generation digital vacuum display meter, the vacuum degree is directly digitally quantified and output, eliminating pointer reading angle errors and facilitating experimental data recording.
③ Equipped with LCD program instrument, the temperature and vacuum status can be visualized at the same time, and it natively supports multi-stage heating and cooling constant temperature process, without the need for additional accessories.
Type II integrated touch screen
① Suitable for key laboratories that have high requirements for human-computer interaction, need to frequently switch between multiple experimental processes, and pursue high-end experience for the entire machine.
② Built-in process curve display, the complete process trend can be viewed in real time during operation, and a large number of process recipes can be stored and called.
③ Adopting the third generation integrated touch screen, temperature, vacuum, time and process curve are all integrated on the touch screen, making the operation interaction intuitive and smooth.
| name | High temperature vacuum drying oven/programmable high temperature vacuum drying oven | |||||||
|---|---|---|---|---|---|---|---|---|
| Product model | UR4‑30LB UR4‑30LPB | UR4‑50LB UR4‑50LPB | UR4‑90LB UR4‑90LPB | UR4‑125LB UR4‑125LPB | UR4‑150LB UR4‑150LPB | UR4‑215LB UR4‑215LPB | UR4‑250LB UR4‑250LPB | UR4‑430LB UR4‑430LPB |
| vacuum control | ①Analog type vacuum gauge | |||||||
| temperature control | Liquid crystal fixed value temperature controller (LB type)/LCD programmable temperature controller (LPB type) | |||||||
| Temperature control range | RT(room temperature)+10~400℃ | |||||||
| Heating method | external heating | |||||||
| Constant temperature fluctuation | ±1℃ | |||||||
| Temperature resolution | 0.1℃ | |||||||
| Vacuum range | ≤133Pa | |||||||
| Supply voltage | AC220V 50Hz | AC380V 50Hz | ||||||
| power | 2500W | 3200W | 4000W | 5000W | 5900W | 6000W | 8550W | 10750W |
| Inner tank size W*D*H(mm) | 320*320*300 | 415*370*345 | 450*450*450 | 500*500*500 | 500*500*600 | 560*600*640 | 600*600*700 | 630*810*845 |
| Nominal volume | 30L | 50L | 90L | 125L | 150L | 215L | 250L | 430L |
| Number of partitions | 1 piece | 2 pieces | 2 pieces | 3 pieces | 3 pieces | 3 pieces | 3 pieces | 4 pieces |
| Circulating water device | External circulating water device improves test turnover efficiency | |||||||
| Vacuum pump set | Carbon steel soundproof cabinet, rotary vane vacuum pump, relay condensation device (if the sample contains too much moisture, a Q-type front-mounted double-effect condensation device must be selected) | |||||||
| name | Program-controlled digital display high-temperature vacuum drying oven/touch screen program-controlled high-temperature vacuum drying oven | |||||||
|---|---|---|---|---|---|---|---|---|
| Product model | UR4‑30LB‑I UR4‑30LB‑II | UR4‑50LB‑I UR4‑50LB‑II | UR4‑90LB‑I UR4‑90LB‑II | UR4‑125LB‑I UR4‑125LB‑II | UR4‑150LB‑I UR4‑150LB‑II | UR4‑215LB‑I UR4‑215LB‑II | UR4‑250LB‑I UR4‑250LB‑II | UR4‑430LB‑I UR4‑430LB‑II |
| vacuum control | ②Algebraic display vacuum gauge (Type I)/③Generation integrated color touch screen (Type II) | |||||||
| temperature control | LCD programmable temperature controller (Type I)/Integrated color touch screen (Type II) | |||||||
| Temperature control range | RT(room temperature)+10~400℃ | |||||||
| Heating method | external heating | |||||||
| Constant temperature fluctuation | ±1℃ | |||||||
| Temperature resolution | 0.1℃ | |||||||
| Vacuum range | ≤133Pa | |||||||
| Supply voltage | AC220V 50Hz | AC380V 50Hz | ||||||
| power | 2500W | 3200W | 4000W | 5000W | 5900W | 6000W | 8550W | 10750W |
| Inner tank size W*D*H(mm) | 320*320*300 | 415*370*345 | 450*450*450 | 500*500*500 | 500*500*600 | 560*600*640 | 600*600*700 | 630*810*845 |
| Nominal volume | 30L | 50L | 90L | 125L | 150L | 215L | 250L | 430L |
| Number of partitions | 1 piece | 2 pieces | 2 pieces | 3 pieces | 3 pieces | 3 pieces | 3 pieces | 4 pieces |
| Circulating water device | External circulating water device improves test turnover efficiency | |||||||
| Vacuum pump set | Carbon steel soundproof cabinet, rotary vane vacuum pump, relay condensation device (if the sample contains too much moisture, a Q-type front-mounted double-effect condensation device must be selected) | |||||||
| name | High temperature vacuum drying oven/programmable high temperature vacuum drying oven | |||||||
|---|---|---|---|---|---|---|---|---|
| Product model | UR5‑30LB UR5‑30LPB | UR5‑50LB UR5‑50LPB | UR5‑90LB UR5‑90LPB | UR5‑125LB UR5‑125LPB | UR5‑150LB UR5‑150LPB | UR5‑215LB UR5‑215LPB | UR5‑250LB UR5‑250LPB | UR5‑430LB UR5‑430LPB |
| vacuum control | ①Analog type vacuum gauge | |||||||
| temperature control | Liquid crystal fixed value temperature controller (LB type)/LCD programmable temperature controller (LPB type) | |||||||
| Temperature control range | RT(room temperature)+10~500℃ | |||||||
| Heating method | external heating | |||||||
| Constant temperature fluctuation | ±1℃ | |||||||
| Temperature resolution | 0.1℃ | |||||||
| Vacuum range | ≤133Pa | |||||||
| Supply voltage | AC220V 50Hz | AC380V 50Hz | ||||||
| power | 3370W | 3970W | 4870W | 5900W | 5900W | 6850W | 9550W | 12750W |
| Inner tank size W*D*H(mm) | 320*320*300 | 415*370*345 | 450*450*450 | 500*500*500 | 500*500*600 | 560*600*640 | 600*600*700 | 630*810*845 |
| Nominal volume | 30L | 50L | 90L | 125L | 150L | 215L | 250L | 430L |
| Number of partitions | 1 piece | 2 pieces | 2 pieces | 3 pieces | 3 pieces | 3 pieces | 3 pieces | 4 pieces |
| Circulating water device | External circulating water device improves test turnover efficiency | |||||||
| Vacuum pump set | Carbon steel soundproof cabinet, rotary vane vacuum pump, relay condensation device (if the sample contains too much moisture, a Q-type front-mounted double-effect condensation device must be selected) | |||||||
| name | Program-controlled digital display high-temperature vacuum drying oven/touch screen program-controlled high-temperature vacuum drying oven | |||||||
|---|---|---|---|---|---|---|---|---|
| Product model | UR5‑30LB‑I UR5‑30LB‑II | UR5‑50LB‑I UR5‑50LB‑II | UR5‑90LB‑I UR5‑90LB‑II | UR5‑125LB‑I UR5‑125LB‑II | UR5‑150LB‑I UR5‑150LB‑II | UR5‑215LB‑I UR5‑215LB‑II | UR5‑250LB‑I UR5‑250LB‑II | UR5‑430LB‑I UR5‑430LB‑II |
| vacuum control | ②Algebraic display vacuum gauge (Type I)/③Generation integrated color touch screen (Type II) | |||||||
| temperature control | LCD programmable temperature controller (Type I)/Integrated color touch screen (Type II) | |||||||
| Temperature control range | RT(room temperature)+10~500℃ | |||||||
| Heating method | external heating | |||||||
| Constant temperature fluctuation | ±1℃ | |||||||
| Temperature resolution | 0.1℃ | |||||||
| Vacuum range | ≤133Pa | |||||||
| Supply voltage | AC220V 50Hz | AC380V 50Hz | ||||||
| power | 3370W | 3970W | 4870W | 5900W | 6850W | 8050W | 9550W | 12750W |
| Inner tank size W*D*H(mm) | 320*320*300 | 415*370*345 | 450*450*450 | 500*500*500 | 500*500*600 | 560*600*640 | 600*600*700 | 630*810*845 |
| Nominal volume | 30L | 50L | 90L | 125L | 150L | 215L | 250L | 430L |
| Number of partitions | 1 piece | 2 pieces | 2 pieces | 3 pieces | 3 pieces | 3 pieces | 3 pieces | 4 pieces |
| Circulating water device | External circulating water device improves test turnover efficiency | |||||||
| Vacuum pump set | Carbon steel soundproof cabinet, rotary vane vacuum pump, relay condensation device (if the sample contains too much moisture, a Q-type front-mounted double-effect condensation device must be selected) | |||||||
| name | High temperature vacuum drying oven/programmable high temperature vacuum drying oven | |||||||
|---|---|---|---|---|---|---|---|---|
| Product model | UR6‑30LB UR6‑30LPB | UR6‑50LB UR6‑50LPB | UR6‑90LB UR6‑90LPB | UR6‑125LB UR6‑125LPB | UR6‑150LB UR6‑150LPB | UR6‑215LB UR6‑215LPB | UR6‑250LB UR6‑250LPB | UR6‑430LB UR6‑430LPB |
| vacuum control | ①Analog type vacuum gauge | |||||||
| temperature control | Liquid crystal fixed value temperature controller (LB type)/LCD programmable temperature controller (LPB type) | |||||||
| Temperature control range | RT (room temperature) +10~600℃ (long-term use temperature ≤520℃) | |||||||
| Heating method | external heating | |||||||
| Constant temperature fluctuation | ±1℃ | |||||||
| Temperature resolution | 0.1℃ | |||||||
| Vacuum range | ≤133Pa | |||||||
| Supply voltage | AC220V 50Hz | AC380V 50Hz | ||||||
| power | 3370W | 3970W | 4870W | 5900W | 5900W | 6850W | 9550W | 12750W |
| Inner tank size W*D*H(mm) | 320*320*300 | 415*370*345 | 450*450*450 | 500*500*500 | 500*500*600 | 560*600*640 | 600*600*700 | 630*810*845 |
| Nominal volume | 30L | 50L | 90L | 125L | 150L | 215L | 250L | 430L |
| Number of partitions | 1 piece | 2 pieces | 2 pieces | 3 pieces | 3 pieces | 3 pieces | 3 pieces | 4 pieces |
| Circulating water device | External circulating water device improves test turnover efficiency | |||||||
| Vacuum pump set | Carbon steel soundproof cabinet, rotary vane vacuum pump, relay condensation device (if the sample contains too much moisture, a Q-type front-mounted double-effect condensation device must be selected) | |||||||
| name | Program-controlled digital display high-temperature vacuum drying oven/touch screen program-controlled high-temperature vacuum drying oven | |||||||
|---|---|---|---|---|---|---|---|---|
| Product model | UR6‑30LB‑I UR6‑30LB‑II | UR6‑50LB‑I UR6‑50LB‑II | UR6‑90LB‑I UR6‑90LB‑II | UR6‑125LB‑I UR6‑125LB‑II | UR6‑150LB‑I UR6‑150LB‑II | UR6‑215LB‑I UR6‑215LB‑II | UR6‑250LB‑I UR6‑250LB‑II | UR6‑430LB‑I UR6‑430LB‑II |
| vacuum control | ②Algebraic display vacuum gauge (Type I)/③Generation integrated color touch screen (Type II) | |||||||
| temperature control | LCD programmable temperature controller (Type I)/Integrated color touch screen (Type II) | |||||||
| Temperature control range | RT (room temperature) +10~600℃ (long-term use temperature ≤520℃) | |||||||
| Heating method | external heating | |||||||
| Constant temperature fluctuation | ±1℃ | |||||||
| Temperature resolution | 0.1℃ | |||||||
| Vacuum range | ≤133Pa | |||||||
| Supply voltage | AC220V 50Hz | AC380V 50Hz | ||||||
| power | 3370W | 3970W | 4870W | 5900W | 6850W | 8050W | 9550W | 12750W |
| Inner tank size W*D*H(mm) | 320*320*300 | 415*370*345 | 450*450*450 | 500*500*500 | 500*500*600 | 560*600*640 | 600*600*700 | 630*810*845 |
| Nominal volume | 30L | 50L | 90L | 125L | 150L | 215L | 250L | 430L |
| Number of partitions | 1 piece | 2 pieces | 2 pieces | 3 pieces | 3 pieces | 3 pieces | 3 pieces | 4 pieces |
| Circulating water device | External circulating water device improves test turnover efficiency | |||||||
| Vacuum pump set | Carbon steel soundproof cabinet, rotary vane vacuum pump, relay condensation device (if the sample contains too much moisture, a Q-type front-mounted double-effect condensation device must be selected) | |||||||