Direct Seawater Injection: Hengsheng Mass Spectrometry's iQuad2300 ICP-MS for Trace Element Analysis at the ppb Level in Seawater
Editor’s note: This article takes coastal seawater from a location in Guangdong as the sample and, without any treatment, analyzes Cr, Ni, Cu and other elements, focusing on examining the spike recoveries of 7 elements and the internal-standard recoveries using the iQuad 2300 under the premise of not using matrix matching and using only the external standard method.
For many procurement users, choosing a reliable and durable product from among the thousands of instrument brands of mixed quality on the market has always been a headache. To improve users’ selection efficiency and help them buy the “big brand, good instrument, excellent service” they desire, Category Pioneers focuses on highly competitive, fast-growing instrument categories and selects the domestic/imported TOP 5 brands in each sub-category for users. They have long concentrated on a specific sub-market, continuously honing their production technology or processes, and have withstood the test of long-term use by thousands of users, ultimately ranking at the forefront nationwide, or even globally, in single-category market share.
Is an instrument good or not? Users have the most say! To help users learn the skills of using instruments and avoid detours and pitfalls, the Instrument Community specially launched the “Instrument Insights” prize essay campaign. In this campaign, users actively shared their insights on the instruments and equipment they have used, including many shares about Category Pioneers instruments. We will extract some of the users’ insights about Category Pioneers instruments to share with our readers.
Today we share the user insights on the Hengsheng Mass Spectrometry iQuad 2300 ICP-MS, a Category Pioneer.
1. Introduction
The analysis of inorganic elements in seawater has important scientific and practical significance for understanding the functioning of marine ecosystems, protecting the marine environment, assessing the impact of human activities, and predicting climate change.
The necessity of element analysis in seawater is reflected in the following aspects:
- Biogeochemical cycles: Inorganic elements in seawater, especially trace metal elements, play an important role in marine biogeochemical cycling processes. These elements participate in every aspect of marine life, from the formation of cytoplasm in primary productivity to protein synthesis. For example, some trace metals (such as Fe, Ni, Cu and Zn) are crucial to the growth of organisms.
- Ecosystem health: Some inorganic elements in seawater are essential trace elements for the growth of marine organisms, directly affecting the growth of marine phytoplankton and their carbon- and nitrogen-fixation roles, and are key regulators of marine primary productivity. At the same time, changes in the concentrations of these elements are also related to the health of marine ecosystems.
- Pollutant monitoring: Some inorganic elements in seawater, such as lead, are mainly pollutants discharged by human activities. Monitoring these elements helps assess the impact of human activities on the marine environment and provides a scientific basis for pollution control.
As is well known, ICP-MS is a powerful tool for element analysis; compared with other techniques, it has the characteristics of simultaneous multi-element analysis capability, a wide linear range, fast measurement speed, a low quantification limit and strong specificity.
When ICP-MS analyzes seawater with a salt content above 3%, the main challenge is how to reduce matrix effects and signal drift to ensure accuracy and long-term data stability. This article takes coastal seawater from a location in Guangdong as the sample and, without any treatment, analyzes Cr, Ni, Cu, Zn, As, Cd and Pb, focusing on examining the spike recoveries and internal-standard recoveries of the 7 elements using the iQuad 2300 under the premise of not using matrix matching and using only the external standard method.
Hengsheng Mass Spectrometry iQuad 2300 ICP-MS
2. Experimental Section
Samples and Reagents
Samples: coastal seawater collected from a location in Guangdong.
Reagents: GR-grade nitric acid and hydrochloric acid; chromatographic-grade methanol; self-prepared 18.2 MΩ·cm ultrapure water.
Element Standard Solutions and Internal Standard Solution
Element stock solution: a mixed element standard containing Cr, Ni, Cu, Zn, As, Cd and Pb. This mixed standard was diluted with 3% hydrochloric acid to obtain a working curve of 5–200 µg/L.
Internal standard solution: Pt, Te and Ge element stock solutions were diluted into one mixed internal-standard solution using 2% methanol solution and 2% hydrochloric acid.
Sample Pretreatment
The seawater sample collected from a coastal location in Guangdong was transferred directly into a PP centrifuge tube and set aside for use.
Instrument
Analysis was performed using a Hengsheng iQuad 2300 ICP-MS. A single helium flow rate in KED mode was used. The unique electronic dilution design of the iQuad 2300 can, at the same flow rate, achieve the ability to remove polyatomic-ion mass spectral interference while distinguishing the degree to which different elements are affected by mass spectral interference, achieving targeted, differentiated anti-interference effects.
Figure 1: Screenshot of the method parameters, in which ΔH is the electronic dilution parameter.
The automatic tuning function within the ICP-MS software was used to optimize the ICP-MS. A Hengsheng autosampler was used as the sample introduction system. The operating conditions of the instrument used are shown in Table 1.
| Parameter | Setting |
|---|---|
| RF power (W) | 1500 |
| Plasma gas flow (L/min) | 15 |
| Aerosol dilution factor | 12 |
| Helium flow rate (mL/min) | 4.5 |
| Sampling method | Three-way online internal-standard addition, peristaltic pump lift |
| Nebulizer type | Concentric glass |
Table 1. Operating conditions of the 2300 ICP-MS.
3. Results and Discussion
Calibration Curve and Detection Limits
Figure 2 below shows the linearity; the linearity of directly testing the seawater series was good, and the estimated detection limits of the different elements were all between 10 ng/L and 584 ng/L. This means that under conventional conditions, an ordinary laboratory using the iQuad 2300 to directly test seawater is feasible. Moreover, this detection limit can be pushed to even lower values through better containers, reagents and a dedicated instrument sample-introduction system.
Figure 2. Calibration curves of Cr, Ni, Cu, Zn, As, Cd and Pb.
Internal-Standard Recovery and Spike Recovery
In the ISTD recovery test of more than twenty injections, the recoveries of all elements of the 3 internal standards were, for the most part, between 95 and 105%; only the first few samples were slightly outside this range, but were also between 90 and 110%. Analysis suggests the possible reason is that the instrument’s equilibration time was insufficient.
The results show that the iQuad 2300 ICP-MS has excellent stability and matrix tolerance. In the analysis sequence, the signals of low-mass, medium-mass and high-mass elements did not show signal drift.
Figure 3. Continuous analysis of more than twenty undiluted seawater sample solutions, with extremely stable internal-standard recovery.
With the internal standard so stable, the matrix effect has already been effectively controlled; to further quantitatively verify the elimination of the matrix effect, a 10 µg/L mixed element standard was added to blank seawater, yielding spike recoveries of 92%–103%.
| Solution | 52Cr (KED) | 60Ni (KED) | 63Cu (KED) | 65Cu (KED) | 66Zn (KED) | 75As (KED) | 111Cd (KED) | 208Pb (KED) |
|---|---|---|---|---|---|---|---|---|
| Spiked seawater | 11.47 | 10.97 | 11.42 | 11.4 | 17.1 | 12.43 | 9.63 | 11.23 |
| Blank seawater | 1.17 | 1.79 | 2.08 | 2.09 | 7.82 | 2.16 | 0.039 | 1.53 |
| Spike recovery | 103% | 92% | 93% | 93% | 93% | 103% | 96% | 97% |
Table 2. Spike recovery of each element.
It is worth noting that: although this brief report did not use a certified reference material, it has already shown that the matrix effect is well resolved. The most interfering polyatomic ion formed in seawater is the NaAr63 ion; in seawater testing of Cu, the difference between the results for the 63 and 65 isotopes was less than 1%. This shows that the KED mode of the iQuad 2300 has relatively thoroughly eliminated this mass spectral interference.
4. Conclusion
Using the Hengsheng iQuad 2300 ICP-MS to analyze 7 elements in undiluted seawater, the internal-standard recovery was stable near 100%, the spike recovery was good, and the mass spectral interference was well suppressed.
The unique electronic dilution design of the iQuad 2300 can, at the same flow rate, remove polyatomic-ion mass spectral interference while distinguishing the degree to which different elements are affected by mass spectral interference, achieving targeted, differentiated anti-interference effects.
This method is simple and easy to implement, requires no accessories or fittings whatsoever, and can serve as a reference for laboratories with related needs.
We welcome users to actively submit contributions! For the campaign rules and more content, please see:
- Instrument.com.cn “Category Pioneers” user-insights / application-case call for papers
- Category Pioneers | Hengsheng Mass Spectrometry (iQuad2300) ICP-MS usage insights: an enormous number of samples every day, yet performance remains robust
- Overcoming the pain points of rice-flour element analysis! Hengsheng Mass Spectrometry iQuad2300 ICP-MS for the quantitative analysis of 20 elements in GBW10045a | Category Pioneers user insights
Campaign page: https://yc.instrument.com.cn/xinde/3/index
Hengsheng Mass Spectrometry — iQuad 2300 series inductively coupled plasma mass spectrometry
After continuous performance improvement, the iQuad 2300 series ICP-MS was launched in 2023. On the basis of the second-generation instrument, the seven-port-valve rapid sampling system was upgraded again, the function of the hexapole collision/reaction cell with axial acceleration was further developed, the one-click start-up function of the computer software was optimized once more, and a brand-new mobile-phone control software was released — all of which, on the basis of robustness and reliability, give the instrument additional advantages such as high-throughput rapid analysis and operational convenience.
Category Pioneers
The leader in a sub-category of scientific instruments.
Focusing on highly competitive, fast-growing instrument categories, it serves the top-five domestic and international first-tier brands in their sub-markets, helping them build the brand image of a leader in their sub-category and become an important decision-making basis for users when purchasing instruments!
If you would like to learn more about the Category Pioneers service, you are welcome to inquire.
The 18th Original Works Competition
The 18th Original Works Competition — the largest online event of Instrument.com.cn — has now officially begun. The competition has always adhered to its original aspiration of “promoting industrial technical exchange and raising the level of instrument application,” building a broad stage for exchange and display for professionals in the field of scientific instruments. Since its founding in 2008, through 17 editions of accumulation, the competition has gathered tens of thousands of outstanding original works. From practical insights on “troubleshooting abnormal spike-recovery assessments” to exclusive tips on “chromatographic column maintenance secrets”; from the advancement path of laboratory accreditation competence to practical solutions for emergency handling of instrument faults … these wisdom-laden words not only engrave the persistent dedication of researchers, but also build a shared hall of knowledge for the industry.
At this moment, we eagerly look forward to your story becoming the next industry classic that is permanently treasured. The submission period for this edition is August 1 to November 30; we sincerely look forward to your joining. Submit now, and let your professional insights and unique experience shine on the industry stage!