InstrumentCube
Products

Home/News/Method for determination of 9 organophosphorus in aquatic products using Anyeep TQ9120
Company News

Method for determination of 9 organophosphorus in aquatic products using Anyeep TQ9120

Instrument.com.cn Oct 21, 2026

introduction

As broad-spectrum and highly efficient pesticides, organophosphorus pesticides are widely used in agriculture and aquaculture environments. They can accumulate in aquatic products such as fish, shrimp, crabs, and shellfish through water enrichment and feed intake. It mainly causes neurotoxicity by inhibiting the activity of acetylcholinesterase. Long-term low-dose exposure can cause potential harm to human liver, kidney and nervous system. It has become an important monitoring indicator for the quality and safety of aquatic products.

Common samples for testing organophosphorus residues in aquatic products include fresh fish, shrimp, shellfish, crustaceans and processed aquatic products. At present, my country has formed a relatively complete standard system for the detection of organophosphorus pesticide residues in aquatic products, mainly based on national standards and industry specifications such as GB 23204-2016 "Determination of Organophosphorus Pesticide Residues in Foods", SC/T 3034-2019 "Detection Method for Organophosphorus Pesticide Residues in Aquatic Products". Establishing sensitive, accurate, and rapid detection technology is of great significance for controlling aquatic product safety risks, protecting consumer health, and improving aquaculture quality control levels. This method is referenced fromGB 31656.8-2021, quantified using the internal standard method.

Instruments and reagents

Anyeep TQ9120Ultra-high performance liquid chromatography tandem mass spectrometrysystem

Acetonitrile(Pure for mass spectrometry, ThermoFisher Company of the United States)

Formic acid (mass spectrometry pure, CNW Company, Germany)

Acetic acid (analytical grade, CNW Company, Germany)

Anhydrous sodium acetate (chromatographically pure, CNW Company, Germany)

liquid phase conditions

mobile phaseA: Acetonitrile:0.1% formic acid water=6:4

column:Waters ACQUITY UPLC BEH C18 1.7μm,2.1*100 mm

Column temperature:40 ℃

Flow rate: 0.25 mL/min

Injection volume:10 μL

Mass spectrometry conditions

Ionization source: Electrospray ionization source (ESI+)

source temperature: 350 ℃

Spray voltage: 4000 V

curtain air: 35 psi

atomizing gas: 30 psi

Auxiliary gas: 70 psi

collision gas: 11

Scan mode:MRM

MRM parameters of the analyte

serial number

Object to be tested

Q1 ion

Q3 ion

CE (V)

DP (V)

1

Phim

299.1

129.0

15

40



299.1

153.0*

0

40

2

fenthion

279.0

169.0

15

40



279.0

247.0*

15

40

3

paminephos

282.3

138.0*

10

40



282.3

156.0

5

40

4

Malathion

331.0

127.0*

5

40



331.0

99.0

20

40

5

Diazinon

305.2

169.1*

5

40



305.2

96.9

15

40

6

Trichlorfon

257.1

108.9*

15

40



257.1

79.0

30

40

7

Dichlorvos

221.0

108.9*

15

40



221.0

79.0

30

40

8

picolinate

325.0

139.0*

25

40



325.0

112.0

35

40

9

Phytotoxic phosphorus

362.9

307.0*

15

40



362.9

289.0

25

40

10

Fenthion-D6

285.0

169.0

15

40

11

Malathion-D10

341.1

132.0

10

85

12

Diazinon-D10

315.2

170.1

20

40

13

Dichlorvos-D6

229.2

115.0

15

40

14

Methylpyridine-D6

331.1

112.0

35

40

15

Phosphate-D10

373.1

228.0

25

85

Note: * is the quantitative ion transition.

Sample processing

Sample processingWeigh about 5 g of sample (accurate to ±0.02 g), add 200μL Mix the internal standard intermediate solution with 25 mL of 1% acetic acid in acetonitrile and 1 g of anhydrous sodium acetate, vortex and mix for 2 min, sonicate for 30 min, and centrifuge at 8000 r/min for 10 min. Take the supernatant and set aside.

Add 500 mg of PSA adsorbent to the reserve solution, vortex for 1 min, and centrifuge at 8000 r/min for 10 min; take 5 mL of the supernatant and blow dry with nitrogen at 45°C. Accurately measure 1 mL of constant volume solution to dissolve the residue, add 200 mg of PSA adsorbent, vortex for 1 min, and centrifuge at 5000 r/min for 10 min. Pass the supernatant through the membrane and use it for liquid chromatography mass spectrometry-mass spectrometry measurement.

Standard curve preparationAccurately pipet an appropriate amount of mixed standard working solution and mixed internal standard working solution, and dilute it with a constant volume solution.The concentrations of palamiphos, malathion, diazinon, trichlorfon, dichlorvos, and picolidinate are 0.5 μg/L, 1 μg/L, 2 μg/L, 5 μg/L, 10 μg/L, 20 μg/L, 50 μg/L, 100 μg/L, 200 μg/L, and 500 μg/L respectively. The concentrations of phoxim, fenthion, and fenthion are 1 respectively. μg/L, 2 μg/L, 4 μg/L, 10 μg/L, 20 μg/L, 40 μg/L, 100 μg/L, 200 μg/L, 400 μg/L, 1000 μg/L series standard solutions for liquid chromatography mass spectrometry-mass spectrometry measurement.

Note: Care should be taken to avoid direct sunlight during the experiment.

linear range

serial number

Object to be tested

retention time

min

detection limit

μg/kg

Quantification limit

μg/kg

linear range

ng/mL

linear equation

1/x2 weighted

Correlation coefficient

r2

1

Trichlorfon

1.207

0.05

0.1

0.5-500

Y =  0.0904015 * X + 0.0299389

0.9945

2

picolinate

1.51

0.005

0.01

0.5-500

Y =  0.0420746 * X + 0.000251938

0.9989

3

Dichlorvos

1.567

0.05

0.1

0.5-500

Y =  0.0210279 * X - 0.000696553

0.9969

4

Malathion

3.329

0.002

0.005

0.5-500

Y =  0.0448372 * X - 0.000746903

0.9972

5

paminephos

3.661

0.02

0.05

0.5-500

Y =  0.0732575 * X - 0.000895656

0.9934

6

fenthion

4.867

0.02

0.05

1-1000

Y =  0.0148444 * X + 0.00408514

0.9910

7

Phytotoxic phosphorus

5.343

0.02

0.05

1-1000

Y =  0.0111751 * X + 0.000105545

0.9978

8

Diazinon

5.379

0.005

0.01

0.5-500

Y =  0.00685666 * X + 0.000138427

0.9978

9

Phim

6.239

0.01

0.02

1-1000

Y =  0.0238693 * X + 0.000558487

0.9901

Precision and accuracy

Object to be tested

Spiked

μg/kg

1

2

3

4

5

6

Precision

Accuracy

Trichlorfon

2

1.53

1.50

1.50

1.53

1.55

1.54

1.46%

76.41%

10

8.79

8.43

7.96

8.66

8.46

8.18

3.62%

84.12%

100

104.66

96.82

103.96

108.69

105.94

104.82

3.80%

104.15%

picolinate

10

9.67

9.46

9.58

9.72

9.44

9.56

1.14%

95.71%

50

50.74

49.31

48.65

49.19

49.76

48.92

1.51%

98.86%

500

505.93

494.32

491.07

495.96

508.43

490.60

1.53%

99.54%

Dichlorvos

10

10.96

10.82

10.88

10.48

10.45

10.76

1.99%

107.23%

50

54.34

52.79

54.66

52.65

54.67

54.55

1.77%

107.89%

500

526.02

511.71

538.13

528.21

514.43

532.77

1.96%

105.04%

Malathion

10

10.40

10.38

10.05

10.05

10.61

10.02

2.41%

102.52%

50

49.20

51.32

51.86

53.91

53.35

51.82

3.20%

103.82%

500

548.58

523.40

532.19

546.16

538.33

497.76

3.53%

106.21%

paminephos

10

10.42

9.86

10.89

10.43

10.52

10.84

3.53%

104.95%

50

50.41

54.63

52.82

52.01

54.60

54.74

3.33%

106.40%

500

532.82

542.72

530.59

540.56

535.01

545.76

1.11%

107.58%

fenthion

20

20.32

19.45

18.08

20.53

19.00

18.45

5.11%

96.52%

100

92.83

94.14

93.87

96.01

97.01

94.27

1.62%

94.69%

1000

929.42

1011.07

1013.75

1023.50

979.47

927.66

4.40%

98.08%

Phytotoxic phosphorus

20

17.92

18.79

18.80

18.99

19.31

18.61

2.47%

93.68%

100

97.31

95.20

94.28

97.35

92.87

96.73

1.91%

95.62%

1000

991.43

998.78

1006.51

998.36

992.65

967.22

1.36%

99.25%

Diazinon

10

9.48

9.82

9.47

9.21

9.71

9.89

2.68%

95.97%

50

46.82

46.59

49.87

45.68

49.14

45.99

3.66%

94.70%

500

453.64

449.84

435.73

461.91

442.30

445.83

2.04%

89.64%

Phim

20

19.23

20.35

18.59

17.82

19.52

20.61

5.45%

96.76%

100

105.60

98.64

109.24

103.59

98.58

109.30

4.63%

104.16%

1000

965.46

1001.38

1049.82

1029.50

1042.83

1053.61

3.35%

102.38%

Summarize
This paper established a detection method for the analysis of 9 kinds of organophosphorus using the ultra-high performance liquid chromatography tandem mass spectrometry system Anyeep TQ9120. It can be seen from the results that this method has excellent sensitivity, stability and linear range and can be used for routine analysis and detection of organophosphorus.