General PF7 series atomic fluorescence photometer
Core Specifications
Product Details
PF7Series Atomic Fluorescence Photometer
PF7A series of atomic fluorescence products are produced by Puji Companyindependently developedAtomic Fluorescence Photometer Products。
“PF73Atomic Fluorescence Photometer"2014Year8monthly gain “Food testing instrument performance competition”gold medal。
The product adopts gas source sequential flow injection technology, dual-beam optical structure and informationized sample management system to solve the problem of poor durability of peristaltic pumps.question, which improves the problem of poor stability of ultra-measurement analysis instruments,accomplishAtomic fluorescence products with no peristaltic pump maintenance and dual-beam calibrationtechnology building model。
√maintenance free
1, Pneumatic flow path system with no wearing parts, getting rid of the maintenance troubles of peristaltic pumps。
2. The syringe uses pure water as medium, which solves the problem of damage to measuring instruments caused by acid and alkali solutions.。
√Adjustment-free
1, Plug and play element lamp technology, no manual adjustment is required when changing lamps, lamp positionGood consistency, the test results are reliable。
2, quartz furnace atomizerheightAutomatically settoWorking area, no visual adjustment required, convenientQuick。
√more stable
1,Double beam single detector optical system, effectively deducting excitation light source drift and fluctuation, mercury test stabilitygood.
2, Pneumatic flow path system, constant pressure and constant flow sampling deviation is small, the same sample can be tested for a long timeThe difference is small.
3, can realize online, reverse, multiple cleaning, small sample residue, and can test the highest concentration。
4, vapor-liquid separator, cooling water removal, stirring and mixing,promotesensitivity.
√More environmentally friendly
1, Adopting waste gas closed diversion technology, the waste gas is discharged outdoors after adsorption treatment through the diversion channel to ensure the safety and environmental protection of the analysis work.。
2. The waste liquid is stored in a closed manner to reduce volatilization. It has an overflow alarm and is safer to use.
√more applicable
1, can be quickly connected to the morphological analysis unit to form an atomic fluorescence morphological analyzer。
2, can be connected with large injection volume trace element testing accessories to meet users’ testing of ultra-micro content samples.。
3, can be connected to micro-volume injection accessories for small injection volumes to meet users’ needs for small injection volumes of rare samples.
Detection limit:As、Bi、Sb < 0.01 μg/L;Hg <0.001μg/L
Measurement accuracy:RSD ≤1.0 %
drift:≤1.5%
Bath sound:≤1.5%
The above data comes from: Enterprise Standard Information Public Service Platform
Instrument configuration:
Flow path: Fully automatic pneumatic sequential injection flow path system
Optical path: dual beam single detector optical system
Others: Optional fingerprint login management system
Optional barcode identification sample management system