WAYEAL Wanyi IC6200 series integrated ion chromatograph

PRICE
Negotiable
Model:IC6200系列
Brand:WAYEAL
Origin:China

Core Specifications

Instrument type
laboratory
Applicable scenarios
Universal
Pump pressure resistance
35MPa
Flow rate range
0.001-10.000ml/min
Eluent flow rate
0.001-10.000ml/min
Maximum operating pressure
35Mpa (host) or 21MPa (eluent generator)
Operating temperature range
4-65℃
Temperature reproducibility
±0.005℃
Eluent concentration range
0-100mmol/L (potassium hydroxide) or 0-15mmol/L (potassium carbonate)
Applications
Medical & HealthcareEnvironmental & WaterAgriculture & FoodBiotechnology & Life SciencesConsumer Products & ToysChemicals & PetrochemicalsMining & GeosciencesEnergy & UtilitiesMaterials & MetalsElectronics & SemiconductorsAutomotive & TransportationOtherPublic Safety & Justice

Product Details

IC6200 series integrated ion chromatographIs a new generation of intelligenceIntegrated ion chromatograph, realizes Ethernet connection, can realize remote control, guidance and software updates, and one-click intelligent maintenance. It has the advantages of high precision, high stability, and intelligence, which can effectively improve the productivity of the laboratory. At the same time, the appearance has been upgraded. The brand-new Wanyi family design is equipped with a ten-inch intelligent large screen and uses ambient lighting design to highlight the high appearance of the instrument and create a dreamy experimental experience for customers.

Instrument features

Liquid leakage alarm

When leakage is detected, the instrument will detect it in time and automatically alarm, allowing automatic shutdown.

automatic range detector

Based on DSP architecture design, the output value is direct conductance value, the detection frequency is up to 100Hz, it is flexible and adjustable, and can realize automatic range function.

Simple pipeline layout

The pipeline design introduction is smooth and clear at a glance, making operation and maintenance convenient and improving work efficiency.

Online emptying

It can realize automatic emptying of the high-pressure flow path and reduce the manual operation of the experimenter.

Peristaltic pump post-pump cleaning function

Used to clean the plunger rod of chromatography pumps to reduce the precipitation of buffer salts and avoid wear of the plunger pad and gemstone rod.

High-definition ten-inch touch screen

Real-time display of the instrument flow path and the operating status of each component, one-click operation, and viewing at any time.

Consumable ID identification and life monitoring

It can realize ID coding and service life monitoring of consumables such as suppressors, and provide effective reminders to avoid reduction in detection efficiency caused by consumables.


One-click intelligent health maintenance

One-click flushing:

With one-click operation, the system can clean the system after the analysis is completed to ensure the cleaning effect, reduce time and cost, and improve work efficiency.

One-click maintenance

With one-click operation, the system can realize automatic maintenance of the instrument, eliminating the need for manual attendance and process operations, extending the life of the instrument.


Precision PEEK material ion chromatography pump

The pump head is made entirely of PEEK and is resistant to acids, alkalis and reversed-phase organic solvents to avoid metal contamination.

The pump head and transmission adopt suspension technology, which greatly extends the life of the sealing ring, reduces instrument usage costs and maintenance frequency. The series dual plunger mode of electronic pulsation suppression technology provides high-precision, low pulsation, and low drift eluent. It has high and low voltage protection functions to instantly protect the entire analysis and detection system.


All-plastic non-metallic flow path

All PEEK pump

PEEK electric injection valve.

The eluent storage tank, wave path pipeline and joints are all made of acid and alkali corrosion-resistant materials such as PEEK, PTFE, and PP.

All-plastic colored high- and low-pressure hydraulic pipelines facilitate customer identification and operation.


High-precision temperature control for the entire system

Built-in column temperature box and high-efficiency heat exchange technology ensure the heating efficiency and temperature control accuracy of the chromatographic column, ensuring the stability of the results

Eluent preheating function: The eluent and sample are preheated before entering the chromatographic column to avoid negative effects such as repeatable peak diffusion caused by temperature differences.

The high-precision, efficient temperature control and temperature compensation functions of the conductivity cell ensure the stability and high sensitivity of detection, provide a wide dynamic detection range, and realize the simultaneous analysis of high- and low-content components.


Electrolytic self-regenerating membrane suppressor

Electrolysis self-regenerating membrane suppression method, reagent-free design, no need for external acid and alkali, and no need for pump regeneration.

It provides continuous and stable suppression capability, greatly improves the stability of analysis, reduces system noise and drift, has fast equilibrium time, no risk of membrane drying and cracking, and has a long service life.

Special suppressors are available for both anion and cation analysis.


Electrolytic self-regenerating membrane suppressor

Automatic electrolytic regeneration anion suppressor Automatic electrolytic regeneration cation suppressor.

Eluent generator (OH, CO32-、MSA)

Eliminating the trouble and errors caused by manual preparation of eluent, users only need to add pure water to accurately produce high-purity eluent with the required concentration by controlling the current, and gradient elution can be achieved without using expensive multi-eluent pumps.

Save manpower and time:Only deionized water is needed to produce eluents of varying concentrations.

Save costs for customers:The eluent generator enables gradient elution on a single pump.

Extend instrument life:Just pump deionized water into the chromatography system, and the pump sealing ring and piston will no longer be corroded by acids, alkalis, and salts, reducing the pump failure rate and extending the pump service life.

Accurate, reliable, and highly repeatable:The eluent generator is connected after the pump and before the injection valve. The concentration adjustment does not need to go through the volume in the pump, so the response is rapid and there is almost no delay.

Automatic gradient elution: accurately generates eluents of different concentrations by controlling current. The entire chemical process is completed within a sealed volume, avoiding errors caused by manual preparation of eluents and pollution caused by exposure to the air, and effectively improving eluent concentration accuracy.


ECD3100 ampere detector (stand-alone version)

The amperometric detector adopts a three-electrode electrochemical cell structure and can realize functions such as DC amperometric detection (DCamperometric detection), pulsed amperometric detection (PAD) and integrated pulsed amperometric detection (IPAD).


AS2800 series automatic sampler

Equipped with a sample cover to effectively avoid environmental pollution;

Supports single-channel sampling and dual-channel sampling analysis;

Support ultra-large capacity samples;

Supports replacement of sample trays with different digits;

Can be used for concentrated injection analysis of ultra-trace samples;

It has various needle washing modes such as rough washing and fine washing.


AS3110 series automatic sampler

Wanyi Self-made: Seamless connection with workstation

Global procurement of key components: electric injection valve, syringe pump, four-choice rotary valve liquid pipeline and high/low pressure connectors.

Dual system expansion design: optional switching valve to complete dual system sampling.

Pipe material: all PEEK non-metallic material.

Multiple sample quantities: 2mL, 120 positions.

Injection mode: full loop, partial, non-destructive injection, auxiliary air pump: used for auxiliary pressurization and inner needle cleaning, refrigeration: optional refrigeration module to preserve samples at low temperature.

Flushing fluid: 2 types of built-in and external flushing fluids can be selected for wider practicality.

Built-in lighting: convenient for users to observe the sampling process.






image.png

Send Inquiry

Please enter your First Name
Please enter your Last Name
Please enter your Company/Organization
Please enter a valid Email Address
Please enter a valid phone number (numbers only, 6-15 digits)
Select Your Country
Please enter your Inquiry

Similar Instruments

Product Categories

Popular Searches